    Does this toilet just push on

    Another option would be to use a flexi pan conn, you can attach that, then push the loo back onto the flush pipe.
  2. K

    Power Flush Disaster

    Oh dear, all that expense for one rad.:unsure:
  3. K

    Baxi 401 Back boiler engineer needed nr Worthing

    As above, no reason you shouldn't get another 20yrs out of that boiler.
  4. K

    Ideal Logic Combi 30 boiler

    Why not? Part of an annual service in my book.
  5. K

    Ideal Logic Combi 30 boiler

    Your expansion needs recharging by the sound of it.
  6. K

    What tool do I need.

    I hate those things, I agree with suggestion above, use can usually get a bit of give and the nut will loosen.
  7. K

    Pipe type and can I use a Hep2o or Speedit elbow?

    That looks like Hep pipe 15mm. you can use either make of elbow to repair it.
  8. K

    Difficult pump change

    If you're going to take the cylinder out, I'd reposition the pump at the same time for future ease of access.
  9. K

    Replacing bathroom tap - simple Q!

    Change tap, get rid of pop up plug/waste assembly/ fit new waste.
  10. K

    Can't Ignite Baxi Bermuda Back Boiler

    I agree, then it will last another 30yrs. those things are bombproof.
  11. K

    Greenstar 28i Junior Combi Boiler

    You need a permanent live & neutral into the Hive which you can take from the boiler, then connect Ls to T1 & Lr to T3. I use 4 core cable
  12. K

    VALIANT ECO TEC

    The mains water pressure has nothing to do with the system pressure displayed on the gauge, they are connected by a filling loop which sounds as though it may be passing, ie, allowing mains water into the heating circuit.
  13. K

    Wiring up combi for s-plan

    The zone valves will have a orange and grey wire, you need to figure out how to use those as your volt free contacts to your combi in order to make it fire. Scribble it down on a scrap of paper, to simplify, 240v to brown wire to switch zv on, then orange and grey to make combi switch on.'...
  14. K

    Stop hot water from hot water tank

    Those black plastic levers often spin on the shaft rather than actually turn it, try removing the lever and use a spanner on the shaft,
  15. K

    What Type of seal?

    I have an intense dislike of plastic tails on fill valves, hence I don't install them, only brass tails, in your situation I would use a flexi ntap connector, they're very gentle on crappy plastic threads.
  16. K

    Gas smell from boiler after switching off CH

    Possibly, the gas valve could be passing, needs checking sooner rather than later.
  17. K

    dripping valve next to hot water tank

    Just needs tightening
  18. K

    Worcester Bosch 28cdi Boiler - Spontaneous Combustion.

    DHW preheat switched on, as said above.