  1. K

    Ariston Combi unidentified problems (Ed.)

    Bin it, the software in those things is hideous when it hits self destruct mode.
  2. K

    Valves position

    Black valves should be in the vertical position
  3. K

    Radiator whistling

    Try opening the non TRV valve fully open and see what happens
  4. K

    New diverter valve. Boiler over heating

    We use brick acid, easilly available & does the job. It's normally the primary side of the plate that blocks from the muck in the system.
  5. K

    What to do with this mess of a toilet inlet

    Easiest way would be to buy a flexi tap connector hose with integral iso valve and attach it onto the copper below the speedfit connector, discard everything else there.
  6. K

    Worcester Greenstar junior - no CH

    Your boiler doesnt have a pilot light. I suspect you don't have a combi boiler boiler either. We need more info. Do you have a hot water cylinder?
  7. K

    New boiler - electric shower question

    I define a power shower as one fed from separate, gravity fed H&C supplies, the unit contains its own pump which provides the desired flow.
  8. K

    Radiator valve - is this the o ring or something else?

    That looks like it has a internal screw for which you will need an Allen key to adjust. You will need to unscrew the whole thing to repair it, using a new O ring, or maybe PTFE tape,
  9. K

    Can you work on valve-to-rad connections without draining?

    I changed a a rad for a heated towel rail for someone today, had to alter pipework slightly to make it neat. Used the bungs as shown above, lost about a litre of water before it sealed, job done.
  10. K

    Boiler burping noise

    OP said earlier he was getting 28mb at boiler
  11. K

    Question about a single pipe heating system

    Ask yourself if it ever worked properly? If it did, what has changed?
  12. K

    Boiler burping noise

    Seemes bizarre that gas supplier can't adjust meter governor to the standard 21mb (+or-2mb), I'd be complaining to them again if it were me.
  13. K

    Expansion vessel or heat exchanger

    As Terry says, shower valve fault
  14. K

    Gas leak alarm

    Why on earth would she suddenly get a gas leak?
  15. K

    Sudden Cold Water From Combi

    As Madrab says, blocked plate hex.
  16. K

    Pump runs when not calling for hot water - y plan open danfoss system

    Your pump may be wired directly to the boiler, in which case, the fault may lie there.
  17. K

    Help! Bathroom radiator not coming on.

    If you've turned the valve clockwise, you will have turned it off. Some of those valves can be repaired when they leak, if not, you'll have to replace it/them. Have you tried opening it fully? Sometimes they stop leaking when fully open.
  18. K

    Ideal Combi c30 boiler - no hot water

    It won't blow up, it'll just switch itself off.
  19. K

    Ideal Combi c30 boiler - no hot water

    Condi trap is full/blocked