  1. G

    Baxi Bermuda no CH but HW working

    in the airing cupboard is there two electrical valves attached to pipe work by the pump , possibly 1 with 3 connections
  2. G

    Water splashing out of drain appliance

    your bottom connection is this for a dish washer if so then its probably left a load of gunk in that elbow dismantle it and clean it out
  3. G

    Moving stop tap above floorboards, terraced house

    but denso might just still walk in ;)
  4. G

    Moving stop tap above floorboards, terraced house

    Is it a modern one in the pavement outside ? Its usually easier to just turn off outside
  5. G

    Can you get thin 22mm pipe insulation?

    might not be to prevent potential freezing
  6. G

    Can you get thin 22mm pipe insulation?

    https://www.wolseley.co.uk/product/center-pipe-insulation-22mm-x-9mm-(2m)/ Local plumbcentre off the shelf
  7. G

    New boiler or not?

    Magna cleans are know as magnaleaks within the trade due to how easy they leak after being touched
  8. G

    New boiler or not?

    no it wont , anyone who has been in the trade will have experienced the mass of jelly in the header tank when the gallon containers of fernox was just added to the header tank . It was never got pulled into the system and just turned into gelatinous mass. If putting it in the tank then drain off...
  9. G

    Boiler Issues

    you have boiler issue then and it needs diagnosing by qualified guy
  10. G

    New boiler or not?

    i have fitted systems that were in for decades with no inhibitor and the water was crystal clear when eventually drained for new boilers. Proper installation stops any fresh water/oxygen ingress
  11. G

    Boiler Issues

    what fuse had blown and what further fuses blew ?
  12. G

    Boiler Replacement

    i gave the figure for the 30kw on post 5
  13. G

    Boiler Replacement

    yeah that will be plenty for the shower
  14. G

    Boiler Replacement

    ideal logic 30kw will give you about 12.4 litres per minute a 24 will give you 9.9 litres the 35 gives 14.5 litres Hw delivery is your first consideration when going for a combi
  15. G

    Old steel gas pipe removal in 1930's house

    50`s internal pipes would usually have been lead or iron/steel cant think of any houses predating mid 60`s that i have worked in that had copper internals
  16. G

    Boiler Replacement

    LOGIC 35 so a combi so will be sized for HW on a like for like 35 it drops down to 7.5kw the 30 drops to 6.4kw
  17. G

    Boiler Replacement

    replace it for another logic be a doddle of a job as all pipes and flue hole should line up saving you labour costs Get someone local through recommendation from family /friends
  18. G

    Boiler Issues

    edit 1 Position is for lpg o position for NG https://www.freeboilermanuals.com/assets/pdf/viessmann/Vitodens-100-W-Compact.pdf
  19. G

    Boiler Issues

    Sounds like the fast blow fuse in the actual boiler has blown then
  20. G

    Boiler Issues

    righthand button on boiler press it see if that makes any difference check / replace the fuse in the switch besides the clock . 3amp Your clock is in the off position make sure its calling for heat