  1. Alarm Engineer

    Pyronix Enforcer 485 comms lost alarm

    485 coms lost is a loss of data to the keypad which is displaying the message. Usually a cable issue on remote keypads, If its the main panel on the enforcer then I guess it would indicate a faulty panel.
  2. Alarm Engineer

    Isolating switch for external alarm bell

    A well installed system should never false alarm, I think you should look at your detection equipment first and the way its sited in relation to the manufactures instructions. A switch wont turn off whist your away if it false alarms & could be switched off by mistake or even worse switched...
  3. Alarm Engineer

    PIR Battery Change Advice?

    Take off PIR lid and silence tamper alert, replace battery then reset system.
  4. Alarm Engineer

    Wiring ZEM32 to Euro 46 Panel

    Yes your right.
  5. Alarm Engineer

    Better solution than PIR brackets

    You need a long drill bit (1/2meter long by 10 or 15mm in diameter) place drill bit in the corner of the coving and the drill bit will flex to your advantage, drill up horizontally, your first go through the coving then the ceiling, once through drill back out and thread cable up. Retrieve cable...
  6. Alarm Engineer

    Euro 46 upgrading bits.

    Press and hold D until it asks for security code, enter 2000 press yes to go through menu and your see keypad volumes. Press A to esc... And yes ideally a 16ohm speaker for all your entry exit tones.
  7. Alarm Engineer

    Menvier TS690 - tamper on non-existent circuit??

    Look whats wired into the AUX Tamper terminals on right side of Panel PCB, usually the internal speaker tamper. Place a link of wire to bypass if not required. Then 0 + ESC should then say Open then Time display.
  8. Alarm Engineer

    Euro 46 upgrading bits.

    In that case your have to prog the output to function to do only one of the following: Alarms : Siren Any Or Entry Exit tones: Entry Exit A 16ohm speaker would work better here imo.
  9. Alarm Engineer

    Euro 46 upgrading bits.

    Yeah neg to neg and pos to pos will, this is what i suggested to test it. You dont want it making a noise all the time hence the neg goes into the o/p on keypad. I presume this should work as your expecting it too.
  10. Alarm Engineer

    Euro 46 upgrading bits.

    PRG on keypad to Neg on sounder + on keypad to Pos on sounder
  11. Alarm Engineer

    Euro 46 upgrading bits.

    Ok, test the sounder by wiring in the + into keypad and tapping the neg on the normal neg terminal, this should produce sound, move the neg wire into the keypad output and test. Let us know what happens? What sounds are you after, alarms only, entry exit only or both?
  12. Alarm Engineer

    Euro 46 upgrading bits.

    What sounder are you using? If its a 16ohm speaker cone type then wire into Keypad OP and +, leave output programmed as 0000 (not used) -no programming required.
  13. Alarm Engineer

    Pyronix euro 46 help

    Engineer menu > Assign Keypads/Readers > Keypad 0 > enable A& B (same for any other keypads)
  14. Alarm Engineer

    Help setting up Texecom Elite 48

    Enginner mode > Setup Users go to each individial users attributes & your see *****C Press '6' to take away the 'C' on each user.
  15. Alarm Engineer

    Help setting up Texecom Elite 48

    In Zone Setup go to the front door circuit setup, go to its attributes and enable "Guard" that will give an instant alarm on part set and a timed entry in full set. Atributes 1 *******G
  16. Alarm Engineer

    Recommendations for hard wired alarm system

    Keep Hardwired, Only go for a system with an LCD keypad (displays full text on screen) and go with a reputable brand such as Pyronix (Euro Mini/ Euro 46), Texecom (Veritas Excel/Premier Elite 24) Honeywell (Galaxy flex) or Scantronic (9448) Some of these have an app too, giving you full control...
  17. Alarm Engineer

    Pyronix enforcer

    Multiple incorrect keypresses at device 0 which is the onboard keypad.
  18. Alarm Engineer

    Orisec

    Who's selling it, cant find a supplier?
  19. Alarm Engineer

    Pyronix Enforcer - Siren Tamper

    Think you can replace the leaf switch on those, we have a custom made PCB & assembly at work so not entirely sure on the mass market ones.
  20. Alarm Engineer

    Pyronix Enforcer - Siren Tamper

    If your getting Siren Tamper then you really need to check the siren again or replace it, Clean starting will not solve anything. The siren has a screw next to the tamper switch which presses against the wall, by turning the screw the leaf switch comes out towards the lid, make sure you hear...