Issues #1, #2, and #3 are major installation defects—gutters must fall towards the drain, swan neck sockets must face upwards to prevent leaks, and a 13 cm gap will let rainwater rot your fascias. Do not release final payment until the roofer levels the gutters, corrects the pipe joints, extends...