    Pyronix Dual Tech PIR changed battery nor saying restore required

    Are the batterys in the correct way? Have the battery voltages been verified? Do the LEDS light up when the batterys are inserted? Are the metal prongs at either side making good contact? Is there any corrosion on the PCB?
  2. Bigsosij

    Remove alarm - Panel Marked ZX 901

    Basically, if the 12v supply is removed from the external siren (ie removing mains and battery power from the control panel), it should sound from it's internal battery. The panel is at least 30 years old so it would be assumed that the bellbox is also, so the bell battery may be no good. Only 1...
  3. Bigsosij

    Remove alarm - Panel Marked ZX 901

    Ladders out first then it that case
  4. Bigsosij

    Pyronix Enforcer beeps for 7 seconds before setting

    It does this whilst arming the wireless devices before the exit period starts. You can stop it by not using any wireless devices.
  5. Bigsosij

    Texecom area group/part set enquiry

    U will have one part set on area A to set the house for bedtime
  6. Bigsosij

    Texecom area group/part set enquiry

    Forget part sets, u need to put the relevant zones in different AREAS as has been stated by a few people
  7. Bigsosij

    Texecom alarm won’t sound when armed

    Should be like this
  8. Bigsosij

    Texecom alarm won’t sound when armed

    Have you wired pirs with 4 or 6 cores?
  9. Bigsosij

    Texecom alarm won’t sound when armed

    Missing EOL resistor (2k2)
  10. Bigsosij

    Pyronix GPRS Not Polling.

    You can get a digi wifi for your existing v10 panel...
  11. Bigsosij

    Texecom veritas LCD panel dead

    Probably got mouses in the walls
  12. Bigsosij

    Pyronix GPRS Not Polling.

    I once asked CSL about this they said they didnt work on 4G. I would try rebooting the panel in the first instance
  13. Bigsosij

    Castle caretech 1700 alarm

    Also 1700 is an ID system
  14. Bigsosij

    Castle caretech 1700 alarm

    User code that is. Code then #
  15. Bigsosij

    Castle caretech 1700 alarm

    Type in the code and it will show the fault on the screen eg F 5 alternating ?
  16. Bigsosij

    Walk Test Showing "1" constantly on Accenta Panel

    Sound like panel is bust then does it do same if u link the zones out directly on the panel
  17. Bigsosij

    Walk Test Showing "1" constantly on Accenta Panel

    All zones are open circuit. I would first rule out any issues with the panel by fitting wire links across 1 or more zones and trying the walk test, of this is ok u will need to determine your zone wiring is correct and make sure devices have 12volts, check if aux fuse has blown. This wouldnt...