  1. CountryFan

    Toilet constantly trickling

    Make sure it’s clear of the side of the cistern and is it adjusted to the correct level?
  2. CountryFan

    Vaillant ecoFIT pure 415 - Faulty Panel Seal

    I think that looks like one of the newer ones, if so, then it’s fine. The older types had the cover sealed all the way across. If the pcb housing is fine and the cover forms a seal all the way around the outer edge then it’s fine. They’re only classed as At Risk as there’s no current danger...
  3. CountryFan

    Two way lighting not working

    Unless it has voltage reading capabilties then please dont as theyre useless for what you need. To be fair, this (in your opening post) shows terminals but further photos do not
  4. CountryFan

    Two way lighting not working

    I have changed lots of stuff too (gas engineer) and have easliy got distracted or whatever and when confirmed voltage it hasnt been correct.
  5. CountryFan

    Two way lighting not working

    Maybe go and buy a cheap tester? Or employ an electrician? Unless you can confirm correct voltages, I doubt wiring advice would be beneficial.
  6. CountryFan

    Screw hole covers for upvc frames

    Any photos of existing ones? Maybe type this into a search engine? upvc screw hole covers
  7. CountryFan

    Bonding

    Maybe this is of some use? https://electrical.theiet.org/wiring-matters/years/2019/75-may-2019/to-bond-or-not-to-bond/
  8. CountryFan

    Is “I cannot see any asbestos” a valid reason to close this case?

    Private or social housing landlord? If the latter point them towards Awaabs law, Riddor and COSSH if the former then probably just COSSH and Riddor.
  9. CountryFan

    Thermowatt immersion heater - cable strain relief

    I think they could be correct, probably just the orientation, for which they cannot assume where the hole will end up
  10. CountryFan

    Thermowatt immersion heater - cable strain relief

    Yes the last photo appears correct, but I can’t find the instructions online, could you post a photo of the bit you mention?
  11. CountryFan

    Cistern only filling part way up/weak flush

    It looks to me like the fill valve is catching on the cistern.
  12. CountryFan

    How to replace a leaky WC Cistern syphon

    Ime, it’s usually the float valve passing water via the internal overflow, not the actual syphons.
  13. CountryFan

    Fluidmaster fill valve

    Not entirely sure, but it's either a slight turn and lift off or just lift off. Maybe this can help?
  14. CountryFan

    Fluidmaster fill valve

    Definitely a fill valve, not the syphon
  15. CountryFan

    Changing soldered joint for push fit/compression

    Pre soldered (possibly Solder ring you’re thinking of) need the pipe clean, fluxed, clean of dirt/debris et al, no water in the pipe and heat applied.
  16. CountryFan

    Is This Boiler Finished And Needs Replacing - Valliant

    Salvageable imo. Might need a new back rail, but ultimately looks like the condense hose has failed (common on this year/model), it even looks like it’s not attached and, if that’s the case, then your boiler man should have turned the boiler off and issued a do not use sticker and warning...
  17. CountryFan

    Cape Verde

    I only saw a bit of it last night. There seemed to be some bias towards Uraguay, and there seemed a lot of shoving. Uraguay deserved a conceded goal after that GK blunder - was it David James in goals? :ROFLMAO:
  18. CountryFan

    Vent pip in loft in the way

    Au contraire https://www.plasticpipeshop.co.uk/75mm-2-12-Grey-PVC-Pipe-10-bar-PN10-25m-Length_p_5317.html, just ain’t cheap!
  19. CountryFan

    Vent pip in loft in the way

    Your last photo shows a white cowl, which is an air admittance valve - can this be swapped with your proposed stack?
  20. CountryFan

    Vent pip in loft in the way

    Yes it can be reduced in size to not less than 75mm for single or 2 storey properties. Or perhaps change the air admittance valve on the other one for the 110mm on existing and vice versa.