What is the span of the beam between the supports
What is the size of the beam
What is the span of the roof between the beam and the inner beam
What is the size of the joists supporting the roof and their spacing
I assume the roof between the inner beam and outer beam is just a flat bit of roof...
Of course its all down to actual calcs and FoS ,not just this is what we always do, 100, 200, 300, would you fret putting a 10m spanning beam if it had no load on it resting on a 50 x 50 angle bolted to a column??
All beams deflect under load , 1/360 or 1/300 span is the general max figure used in BS standards but can be tighter depending on the circumstances i.e. say above a glass partition (extreme case). At 10m the deflection could be 33mm which would be unacceptable in your case and hopefully the...
OK just making sure that the supply through the field/your property is WC responsibility and as such you are liable to adhere to whatever conditions they dictate
Possibly due to lintels have a stated SWL and this puts any bearing pressure with the usual specified 150 bearing within the capacity of even soft brickwork and BC know this, not fact ,just an hypotheses.
Well he has 2 choices then, point it up and hope it lasts for a few more years or pay some jobbing builder to demolish and rebuild at substantial cost, do you know any?