Search results

  1. T1GERIII

    Pyronix Enforcer - Wireless JammWZm issue

    As above old sensors can cause this and also low batteries in local wireless devices. Another cause of jamming is newly installed LED street lights. turn wireless jamming to 000 and have done with it.
  2. T1GERIII

    PowerMax Visonic - Landline

    Yes it will work as a stand alone bells only system. You’ll need to disable the communications inside the engineer menus.
  3. T1GERIII

    Texecom adding another ricochet expander

    I second the method of deleting the first expander and relearning all onto the 32 way. We have had a couple of sites where the supervision issues are constant on two 8xp, swapped them for a 32 and no more problems fully meshed
  4. T1GERIII

    Pyronix V11 keypad.

    Easiest method is using smart device then any character of the password can be input
  5. T1GERIII

    Pyronix Enforcer sending thousands of text messages

    If the system is maintained then surely you can get your security company out to remove the SMS feature for the time being?
  6. T1GERIII

    Texecom Premier Elite PIR

    The jumpers in the picture aren’t across both pins for resistance…
  7. T1GERIII

    Is this cable OK for maglock and keypad?

    We use 8core and double up on 12v + -
  8. T1GERIII

    Texecom Premier Elite 64w wireless keypad zone

    I thought they auto-learn as a MASTER type
  9. T1GERIII

    Texecom Connect SmartCom

    As sparky said re-program, Wintex won’t allow you to send premier data to an elite panel it’s conflicting.
  10. T1GERIII

    Pyronix Siren issue

    The screw shouldn’t be an issue, unless you’re getting a tamper fault. Did you do a bell test following replacing the battery? I’d be inclined to delete the bell from the system and re-learn
  11. T1GERIII

    Pyronix V11

    I think key 1 does some characters but not everything . - / off the top of my head
  12. T1GERIII

    Pyronix HomeControl App No Longer Working

    If your installer can’t see any requests for phone authorisation then I’d suggest double checking your System ID is correct in the app. Be careful of the 0/Os and 1/Is
  13. T1GERIII

    ProControl+ playback

    Static IP address will allow for sped up playback on ProControl. Other than it it’s setting up a DDNS to log into the NVR which would also allow the sped up playback
  14. T1GERIII

    Scantronic 9800 to 9651 conversion - open Zone

    Have you programmed the OP3 as bigsosij recommended earlier?
  15. T1GERIII

    Scantronic 9800 to 9651 conversion - open Zone

    no aux fuse to pull on a 9651, but I agree wouldn’t bother down powering you have two 12v aux outputs so should be plenty of room to get the cables in
  16. T1GERIII

    Scantronic 9800 to 9651 conversion - open Zone

    Shocks require a 12v aux feed, so should have a pair wired into the zone and a 12v feed from AUX
  17. T1GERIII

    Problem with door sensor on enforcer enf/kit3?

    This… heavy handed screwing of the tamper back plate is 9 times out of 10 tamper problems on DC
  18. T1GERIII

    TV/CCTV/NVR No signal

    This one is painful
  19. T1GERIII

    TV/CCTV/NVR No signal

    NVR output mode may need adjusting , can you test it on VGA output?
Back
Top