Search results

  1. M

    Do many workplaces not allow mobile phones ?

    There was a couple of things going on with schools They were taking away the mobiles so they could teach Then they we’re replacing the blackboard with laptops and that hasn’t worked out The students were using the laptops for everything except schoolwork
  2. M

    Do many workplaces not allow mobile phones ?

    That’s a large part of the problem Is there any actual legislation covering this issue Probably just a workplace makes the rules and take or leave it
  3. M

    Why is Andy moving number 10

    Had Andy burnham done anything yet The whole thing with the vat on electric smacks of window dressing They have to claw back the money from somewhere else
  4. M

    Do many workplaces not allow mobile phones ?

    As in you have to hand over the phone on workplace entry It goes in a box until work is finished
  5. M

    Do many workplaces not allow mobile phones ?

    I know schools do it but I’ve only just heard of it for routine work I think they don’t want anyone filming inside
  6. M

    Interesting Regulation of Yesteryear

    I can see how it would read as a separate switch per point but i don’t think it actually means that Anyway very interesting topic
  7. M

    Fused spur arching

    Do dryers need a break :D Good question :giggle:
  8. M

    Interesting Regulation of Yesteryear

    It means every point in an installation must be capable of being switched off Except for sockets that are readily accessible
  9. M

    Interesting Regulation of Yesteryear

    Is this an early rule involving both control and isolation Isolation is a different matter now separate to control of lighting
  10. M

    Interesting Regulation of Yesteryear

    I'm not reading it as every light must have a separate switch
  11. M

    Interesting Regulation of Yesteryear

    When rules were simple
  12. M

    RCD adaptor won't reset...

    Without thinking about it too much they're probably ok for polarity but not the fault loop impedance
  13. M

    New ceiling lights fitted by Electrician - questions?

    It's a problem alright class 2 metal equipmrnt I've even seen some 2-wire stuff live , DVD players
  14. M

    RCD adaptor won't reset...

    I’ve seen plenty of faulty/failed rcds Some on new work not tripping within parameters and some on older work not tripping at all
  15. M

    RCD adaptor won't reset...

    Do you mean a main rcd for the entire installation ? That’s best avoided where possible imo All 30ma rcbos is the best way imo
  16. M

    Discover More Home Automation really?

    One of the best tv things I ever did was fit 4 flush pirs indoors 2 in hallways 1 in kitchen and bathroom That’s my idea of smart control
  17. M

    Car Insurance. I expect mine is going to go up.

    Wait and see I was at fault in a minor accident and my insurance went down at renewal
  18. M

    lighting adapter to 3 pin plug

    I was about to post a similar query to FrodoOnes post If i'm not mistaken it would be very unusual for a appliance cord to become overloaded As i posted already , afaik some appliance cords are not protected against overload . Small cords fused at 13A
  19. M

    lighting adapter to 3 pin plug

    If i’m recalling correctly appliance cords are now fused at 3 or 13 amp Over 700w ? appliance is fused at 13amp Some 13 amp appliance cords are not overload protected ie ; 0.75 and 1 mm cords fused at 13 amp
  20. M

    lighting adapter to 3 pin plug

    Overload isn't a big issue with appliance cords is it Isn't the cord mostly protected by the load being sized to match the cord ?