  1. bhm1712

    Breathable Roof Membrane - Recommendations

    How about this one? https://www.roofingmegastore.co.uk/protect-viking-air-type-lr-air-and-vapour-permeable-underlay.html
  2. bhm1712

    Armoured Electrical Cable

    do they really!?
  3. bhm1712

    2.5mm cable for extra sockets

    Whilst it’s not 100% guaranteed to confirm it for a plethora of potential reasons, usually one can say with some level of confidence that if a socket has 2 sets of cables coming into the back box, both connected to the terminals of the socket itself (both browns/ reds to live, both blues /...
  4. bhm1712

    2.5mm cable for extra sockets

    It is perfectly allowable to run a spur socket from an existing ring final socket in 2.5mm, regardless of whether the existing socket is a single or a double. My understand of what you have done (added 3 single Spurs from 3 different existing sockets) is that you have done just that. The only...
  5. bhm1712

    "Savings" calculation for solar PV with storage batteries?

    It’s an 8kw Solar PV system with 2 6.5kwh battery units.
  6. bhm1712

    "Savings" calculation for solar PV with storage batteries?

    Another thing to consider with battery storage (at least with ours) is that we benefit from economy 7. If the batteries are not fully charged during the lower light winter days, we can charge the batteries overnight using the lower rate economy 7 electricity and then use the battery and solar in...
  7. bhm1712

    Extraction fan in bathroom

    In my opinion, the only type of extract fan that is really worth fitting are the inline duct fans that move circa 300m3 of air an hour. just fitted this one and it works fantastically. The previous fan like yours did little to remove any condense from the room...
  8. bhm1712

    Change internal (for outside light) single switch to a double switch for external cctv camera

    I mean, it’s not against any of the BS7671 regs, infact there is a reg which states that you may infact do this. I have done it myself numerous times, but I always offer the option of utilising a 5 amp 3 pin plug and socket as opposed to a 13 amp socket. This completely helps in preventing any...
  9. bhm1712

    Balancing question

    You think the design of gas fired central heating is a problem…just wait until the heat pump takes dominance. Jesus Christ wept. Totally agree. There are very few boiler installers and heating fitters who actually take the time to calculate the proper requirements, radiator sizes etc. Part of...
  10. bhm1712

    Balancing question

    There is no point having a condensing boiler if the system isn’t to be balanced - is yours a condensing type? When I balance a system, I refer to the boiler manual and attempt to balance so that the recommended temperature differential (referred to as “Delta T”) across the flow and return is...
  11. bhm1712

    (Another) leaking rad valve question

    When you undo that nut, you will spring a leak at leak point 2 and 1 unless the system is empty. i successfully applied ptfe tape to the threads on the stuffing gland on the twin entry valves at my old house but did it with the system empty of course. This lasted me until I replaced the valves...
  12. bhm1712

    Keeping boiler return temp lower as TRV’s close down

    Got a feeling that the installers left it on 18kw range. Time for gas man. Can’t run pump any lower as the run is long and the last rads don’t get good flow on setting 1.
  13. bhm1712

    Keeping boiler return temp lower as TRV’s close down

    well this thread turned into something else LOL! just going back for a minute to my issue, what do you think the likely cause of the rising return temp the longer the boiler runs for? Even on its lowest modulation percentage. If it’s something i need to get the gas man out for i will do that...
  14. bhm1712

    Changing a circuit breaker

    I don’t think advising people to work in that way is a great idea. With none lethal mediums, absolutely. But not with electricity. The fact that he seemingly has no measurement equipment suggests he can’t even check for dead to make sure the main switch is working or that nobody has done the...
  15. bhm1712

    Changing a circuit breaker

    Simply swapping supplies over is not the answer nor is it a valid way of fault finding. You need to check for voltage present on the outgoing side of MCB supplying the garage unit in your homes consumer unit and if there is voltage present there - also at the incomer to that garage unit. If...
  16. bhm1712

    How to attach thermostat to boiler?

    I agree with BlueLoo, or words to that effect. You could even throw in the relevant paragraph from the building regs regarding boiler installation since they’ve now admitted the boiler was installed last year which falls into the post 2018 Regulation update time period (against the law to...
  17. bhm1712

    3 pin socket

    What Terry said
  18. bhm1712

    3 pin socket

    If you want to remove it you first need to consider what you’re going to do with the wiring. Simply removing the face plate means that the wires supplying it will still be live. Are you able to disconnect the supply at the fuse box?
  19. bhm1712

    3 pin socket

    It’s a 5 amp socket. Usually used (in the past) for powering a low power device or plug in light from the lighting circuit.
  20. bhm1712

    Keeping boiler return temp lower as TRV’s close down

    A bit like Harry, I have a condensing boiler (all be it a heat only boiler with no internal pump control) with existing controls, all be it “dinosaur age” controls. Simply consists of a wireless room stat, timer and TRV’s. I have no intention or desire to spend hundreds of pounds upgrading the...