  1. T

    Basin Waste to P Trap

    As long as you are not cross threading the plastic nut ,it's highly unlikely that 2 traps are the problem . The trap should screw on easily. You may have a European waste fitting that is not a BSP thread. ******* Edit ,just seen your added pics ,and it's now obvious that the inner diameter of...
  2. T

    Basin Waste to P Trap

    Looks fairly standard to me too. Is the seal in the trap in good condition ?
  3. T

    Little leak in boiler

    As above ,try to tighten the nut on the left hand side
  4. T

    Little leak in boiler

    Reduce the file size maybe ?
  5. T

    Little leak in boiler

    Posting pictures directly onto this site would be preferable. Not everyone will click onto a link to who knows what.
  6. T

    Little leak in boiler

    No pictures to view ??
  7. T

    Kitchen sink waste pipe fittings?

    There is a rubber seal missing from that compression fitting. Is it inside the elbow ?
  8. T

    Cold water pressure drop

    Is your mains cold water stopcock fully open ? What is the flow rate from your kitchens cold tap ( how many litres of cold water do you get from it if you time it running fully for 1 minute)?
  9. T

    Immersion heater thermostat water getting into tube

    If you remove the stat ,and connect the incoming live directly to the element ,does the RCD still trip instantly ?
  10. T

    Immersion heater thermostat water getting into tube

    What trips , RCD ,MCB, RCBO ? Does the trip happen immediately the element is turned on ,or sometime afterwards?
  11. T

    Electrical vertical radiators/panels

    Did they ever heat fully ?
  12. T

    Radiators not working but...

    If a radiator isn't heating up there is no flow through it ,so the x400 will do nowt as far as that radiator goes.
  13. T

    Vaillant Boiler fault?? Egg timer, water flow in air gap

    Call out an engineer. If you want to save water,close your mains cold water stopcock. Put it on ,as and when you need water.
  14. T

    Radiators not working but...

    How many rads don't heat up currently ? Close the TRV ( or wheel head if no TRV) on all rads that currently heat up. See if any cold rads now heat up. Report back.
  15. T

    Is there still a leak ?

    It looks like the staining on the wall has been there for some time, and from the original leak. If you were expecting the staining to just disappear once the leak was stopped ,that's unlikely to happen. With regard to the 14 year old boiler ,I personally wouldn't keep spending money on it now...
  16. T

    Sentinel TotalGuard Leaking from bleeding valve

    Take the bleed valve out ,if there is a plumbers merchant open near to you take it there to get a new O ring. If not ,wrap PTFE tape around it's thread and re fit it . Get a new O ring when possible . It looks like the leak may not be from the bleed valve though .
  17. T

    Washing machine plumbing into floor waste.

    Yes ,that standpipe/ trap from Screwfix is what you need . You would use a short length of 40mm waste pipe horizontally from the trap to an elbow ,and from the elbow another piece of pipe , vertically down into the boss.
  18. T

    Washing machine plumbing into floor waste.

    Fit a standpipe and trap,and from that pipework into the black boss ( reducer) in the floor.
  19. T

    Waste pipe compression fitting question

    It's fine ,don't overtighten it. The slip ring on other fittings is essentially to prevent the rubber seal from twisting / misforming, providing even pressure onto it.
  20. T

    Upstairs rads getting hot, downstairs not at all.

    Indeed , unfortunately there is a limit to what can be diagnosed remotely. You asked for " parameters",and if things could be "narrowed down" to lessen the chance of being " burnt". The information given by all the contributers has hopefully given you some clarity in that regard, and I sincerely...