Search results

  1. Exedon

    Can i sync the EPH CP4i using ember app to thermostat?

    If you got your ephcp4i as a set and you have linked the gateway to yor WiFi yes you can do all settings from your phone . It's a very quick easy set up.
  2. Exedon

    Old hep2o pipe

    Yes always insert same manufacturer as tube.
  3. Exedon

    Can someone tell me how to isolate my hot water please

    Lever valve on back wall with red handle If installed correctly should push down (fall to off)
  4. Exedon

    Why are there no old school heating engineers?

    I'd Certainly try a chemical flush you can probably do the drain down and refill yourself. If it works cost of power flush saved.
  5. Exedon

    Replace traditional with bar mixer shower

    As above ive managed to do it couple of time when pipework in stud wall using a fast fix kit. By the way matt black brasswear soon looks crap unless you have a obsessive cleaner.
  6. Exedon

    Why are there no old school heating engineers?

    For anyone with half a idea strait forward. Undoubtedly blocked near pump/open vent cold feed connection. Repipe add decent filter refill add X400 run for 4 weeks drain cold flush if needed . Refill adding inhibitor. Run of the mill stuff but not as well paid as throwing a combi on wall.
  7. Exedon

    Central heating layout. This should work, right?

    Take you spoke to Worcester? Doubt they know one end of a camray from another. Which mode of camray? 3 or classic? Perfectly simple to convert to sealed system done many some from new others retro fit.
  8. Exedon

    Why are there no old school heating engineers?

    But a young one ! First fitted a boiler (under supervision) in early 1969 vulcan autostat. Still working fitting a 70kw Grant next week. As above don't get a combi especially from s box slinging team.
  9. Exedon

    Leak between stopcock and water meter

    Yes the white hexagon is shut of valve. There should be a black plastic extension to fit in it . Br carefully not to tighten down too much I've seen then open again. But as mentioned from your boundary onwards the service is your responsibility.
  10. Exedon

    Central heating layout. This should work, right?

    Probably not what you want to hear but I would seriously consider converting to sealed system. Simpler pipework no open vent or feed tank. With existing boilers we generally run system at 0.2 bar above system head.
  11. Exedon

    Central heating layout. This should work, right?

    I would strongly advise against a combined vent/feed . I used to see them on a regular basis (heating team in this area were very fond of them) odd ones can be OK but I've regularly found systems to be absolutely filthy. Plus as already mentioned combined vent/feed systems are notorious slow &...
  12. Exedon

    Riello RDB1 skips a beat

    Is your boiler installed on a standard low level flue?
  13. Exedon

    Riello RDB1 skips a beat

    Probably needs eye's/ears on! Take it you have a combi?
  14. Exedon

    Toilet flushing issues - seems waste pipe plumbing at fault

    First it's not exactly unusual for a modern wc not to clear first flush However that soil connection is absolutely dreadful I take it the contractor arrived on horseback? As above loose the flexi id have probably cut clay under collar then a suitable adaptor 90°bend and solid pipework...
  15. Exedon

    Preventing leaks on recessed 1/2” shower outlet connections

    Your really over thinking it! As above if they are outlets they are under next to no pressure. Use loctite 55 when it starts getting tight and in correct orientation stop. You can 'back ' loctite 55 up to quarter turn even on pressure connections.
  16. Exedon

    Older-style toilet / dimensions question

    I've recently fitted a 450 x 250 chrome flush pipe made by bristan (heritage) cost over £40 but quality was stunning.
  17. Exedon

    TMV constantly leaking in gasket inlets

    Assuming face's are flat just change washers either rubber fiber or we now use kevlar washers on flat faced joints. Don't over tighten.
  18. Exedon

    camray 5 150/200 settings manual

    You must have found same data sheet I have! Agreed may have been inadvertently set for gas oil at some point. The data sheet says flue gas temperature at test point presumably boiler test point. From memory on the camray 5 there was often a large difference from temperature at boiler test...
  19. Exedon

    Hamilton mixer shower Cartridge

    Try shower doctor.com I wish you luck with valve been from Wickes. We always use someone like Bristan or Mira for brassware way more chance of spares been easily available.
  20. Exedon

    camray 5 150/200 settings manual

    Where are you measuring flue gas temperature ? What type of flue?
Back
Top