Search results

  1. J

    Combi with hot water tank - no HW

    Thanks everybody. It was a jammed valve. Not sure if the motor also burnt out, but I'll save that for another day. You have all been fantastic, thank you.
  2. J

    Combi with hot water tank - no HW

    I feel like I am getting closer, but your expert advice thanks. I removed the head body and I think the valve was stuck, it's moving about a 1/4 of a turn now. A question as always please, what activates the microswitch? I thought it was the gold lever but on manual there is a gap and it...
  3. J

    Combi with hot water tank - no HW

    Thanks, you are correct. Even though I changed the motor in the other one :) :)
  4. J

    Combi with hot water tank - no HW

    Thank you so much for your advice Madrab.
  5. J

    Combi with hot water tank - no HW

    Quick update, I havs replaced the motorised valve motor but no difference. I thought I'd eliminate something else! When putting the valve into manual I get resistance. I thought when it was open there wouldn't be any resistance.. the timer is set to on..
  6. J

    Combi with hot water tank - no HW

    Hi, also a quick question. If the microswitch has gone, putting the valve into manual won't make any difference? It sounds as though I will need a whole new motorised valve unit as the microswitch is part of the unit. Over to the pros. And finally if I completely replace the valve (v4043) do I...
  7. J

    Combi with hot water tank - no HW

    Thank you, great dvice. I replaced the top ones motor about three months ago as it had failed and I wasn't getting any CH. Therefore, I assume the bottom one is HW amd maybe at fault. In answer to your question, I removed the timer and connected the Live to HW (terminal 3) on the backplate but...
  8. J

    Combi with hot water tank - no HW

    This forum never ceases to amaze me, thanks so much guys.. I've added some pictures, if that's ok.
  9. J

    Combi with hot water tank - no HW

    Its a Greestar CDi Classic
  10. J

    Combi with hot water tank - no HW

    Hi, I wonder if somebody can help me please. I have a HW systems fed by a Worcester Combi boiler. One side of the house takes the hot water direct from the boiler, the other uses the tank from the previous gravity fed system. Whilst the water direct from the boiler is hot, the tank doesn't...
  11. J

    Shower pressure

    Hi, the latest. I fitted a new isolation (full bore) valve as the old one had failed. Don't know where the rubber seal has gone! I also fitted a guage to the pressure reducer. It shows approx. 3.75 BAR. I tried to adjust the valve but it showed no difference. Interestingly, there wasnt a...
  12. J

    Shower pressure

    It's a Deva. The old one wasn't any better.
  13. J

    Shower pressure

    Thinking about it, like you do. If I fit a gauge to the reducer and find out the bar and match this to a booster on the hot pipe - should this technically work?
  14. J

    Shower pressure

    Very helpful, thank you.
  15. J

    Shower pressure

    Thanks, I wondered that and the pressure to the property is good; although I know it's as good as what's throttled at the pressure reducer. I assume that if the hot is low pressure then the reducer is also turned down to low.. I don't know how old the pressure reducer is, but more than 20...
  16. J

    Shower pressure

    Sorry, I missed that bit: thermostat mixer. I have replaced it with a low pressure mixer.
  17. J

    Shower pressure

    Hi, I wonder if somebody can point me in the right direction please? My mothers shower does not activate unless the head is dropped below her running bath taps. After that and turning off the bath taps everything is fine. The hot water is fed from a gravity system, with the tank on the floor...