  1. Exedon

    Worcester Heatslave oil boiler - lockout after draining and refilling system. Can't figure out why.

    Have a look on rielloburners.co.uk they have fault finding flow charts on there.
  2. Exedon

    Worcester Heatslave oil boiler - lockout after draining and refilling system. Can't figure out why.

    As above try moving fan blades I'd also be checking oil pumps not tight . Also known for pump side motor bearing to be tight. I'm certainly not a fan of the digital control box either seen them fail after seized pump/motor.
  3. Exedon

    Bath surround

    It arrived where it is in one lump! I know it's a pain but it's just disconnect pipework and lift . If it needs a couple of mates get the beer in.
  4. Exedon

    Can't find soil stack, is it shared?

    Having done many newbuilds you will almost certainly be a AAV buried in the boxing in your bathroom. On some sites the specifications were vent one in 6 property's all others Aav's. Apart from failed aav's the real fun starts when someone with the correctly vented stack has a bathroom change...
  5. Exedon

    Fixing wooden board to tiles

    Short end of 15mm chrome pipe cut as spacers simple.
  6. Exedon

    Trumps attack on Iran - 2026 edition

    Absolutely the HMS Conqueror using Mark 8 torpedoes. Sisters husband was the communications officer on board.
  7. Exedon

    Un-demanded heating

    We have had a number of replacement honeywell 2 port heads with the white wire. Instructions just say to terminate safety when used on S plan. The white wire is live when valve closed used on C plan.
  8. Exedon

    Adding an additional rad

    Not much point altering the drops to 15mm without taking them right back to wherever they start. Is your 10mm a manifold system or reduced tees? Is existing rad a double or single. I assume you have a tank feed system?
  9. Exedon

    Worcester Heatslave II 25/32 oil pump bleed screw leaking oil

    Yes just remove existing extension and replace. Then all back to normal.
  10. Exedon

    Worcester Heatslave II 25/32 oil pump bleed screw leaking oil

    That doesn't look to be an original part . Difficult to know what going on . Id Just change it look for Riello pressure gauge extension they come with a new O ring.
  11. Exedon

    WB heatlave not responding to stat requests - otherwise working

    Look for Heating world of spares. Search on there for Worcester diverter valve. They have correct part in stock. The one above will not do. That boiler requires a diverter valve Most 3 ports are mid position valves work differently.
  12. Exedon

    Adding UFH to Y-plan system

    Or just get shut of Y plan valve (it will fail) and do S plan +.
  13. Exedon

    WB heatlave not responding to stat requests - otherwise working

    Very rarely full valve just the head But if you get completely valve try changing head first then if necessary change the lot. They can be err interesting to change!
  14. Exedon

    WB heatlave not responding to stat requests - otherwise working

    If you do change the power head you must use the correct one. Search with numbers on your existing valve. The head for the more common V4073A will not do.
  15. Exedon

    WB heatlave not responding to stat requests - otherwise working

    You need the instalation instructions they are available on line if you don't have them. The 3 port valve are known to fail you must use correct replacement. That old model uses relays that are also known to fail. You need a multimeter and boiler instalation manual and follow the flow chart.
  16. Exedon

    Whistling TRV

    Whilst current trv's are bi directional occasionally you get one that's noisy when closing. I'd be betting it's on return side of rad. Just change it and move on.
  17. Exedon

    newbie - 15mm plastick pipe Softener inlet (Mains) leak - Help!

    Not the best job on earth! Just get a couple of 15mm compression cones short end of 15mm copper and replace damaged section. Maybe a couple of wraps of ptfe on cones before assembly.
  18. Exedon

    WB heatlave not responding to stat requests - otherwise working

    That's the flow switch The 3 port diverter valve sits above the pump Grey plastic head . Which model heatslave? (Not the output) They have made quite a number! Has yours got green plastic on front panel?
  19. Exedon

    Weather compensation sensor with Hive on new combi boiler

    Agree with cp4i nice bit of kit with a 5 year warranty. We have a number fitted to ideal vogue's with weather compensation works really well.
  20. Exedon

    Not Getting Hot Enough!

    If you boiler is due for servicing crack on otherwise all the symptoms you are describing are almost certainly caused by restricted pipework. The picture i attached was from a 11 rad system that was somehow still sort of working ! Short Cycling very sluggish eventually boiler cut out on...