    Vokera Linea 28 hot water issues and presure drop

    I thought we were all rgi's on this forum
  2. B

    Pipe arrangement to combi-boiler with leaking valve.

    Cut it out and fit a proper fill loop kit.
  3. B

    Vokera Linea 28 hot water issues and presure drop

    The main hex is inside the combustion chamber,remove the panel on the from it has about 6 screws securing it, look at the insulation panels if there is any damp stains on it or if the main hex has any green staining then the main hex will need changed, as for the non return valve its on the...
  4. B

    Vokera Linea 28 hot water issues and presure drop

    The main hex on linea's can leak, check the insulation panels if there's any damp marks on them suspect the ain hex for your pressure loss, as for your hot water problem it sounds like either the plate hex or the non return valve at the plate hex could be choked=-)