  1. O

    Tile Vents???????

    Nice one mate, so any idea why these tile vents would have ben fitted?? What differance does the window having a trickle vent make???
  2. O

    Tile Vents???????

    Sisters just moved into new house, just been round to turn on heating, anyway theres a bit of mould in front bedroom all round window, and in corner of room same wall as window, but a good 4 ft away The loft has 2 tiles which are vents, the felt underneath has just been ripped and left...
  3. O

    New Central Heating system now 4 years old - flush ?

    Also, what you are proposing to do, is add a cleaner and "Drain" not "Flush" Unless you have a machine, maybe you do?? Neither will do any harm
  4. O

    Can this be repaired?

    I totally agree, but if it aint down if black and white and my arse is in court, what will they say to me???? Chances are it will never kill any1, and the older type naturally asperated burner type models, manufacturers seals are generally poor especially where there are sheet metal folds...
  5. O

    Can this be repaired?

    If the case has been drilled, then it needs a new case, end of, anything else would be in contravention of Ideals spec which is not allowed 45 years, i can assure you, if someone at BG wanted to loose there job then yes they could seal it by many other ways in which im very confident it would...
  6. O

    Fernox DS40 through HW cylinder coil safe?

    Fair enough, i will have to stand corrected as i have never used it, find it hard to believe its that good, as why wouldnt ppl just use this instead of flushing, much easier and cheaper and according to you with the same results :?:
  7. O

    Fernox DS40 through HW cylinder coil safe?

    If a system is Full of sludge how will putting a chemical in get rid of all the sludge? Powerflushing after using a desludger and then treating afterward will not remove 100% of magnatite, so how will putting it over everything and just leaving it there do much? Ive just realised its a...
  8. O

    Magnabooster

    Why not? Gas men are working for 2 cheap a price all to often, we are skilled tradesmen, and £209 for this job is fair in my opinion I may charge more, depending on job, but would have to see them, i have ppl buying them for much higher than that with no qualms But then again you get...
  9. O

    Magnabooster

    Mains Pressure CH System, you mean Pressurised system? Yes always worth it, will pro-long life and maybe even increase you're efficiency, can make the boiler last longer also, stop ****ty brakdowns/ leaks Magnabooster is the best built domestic filter on the market £209 is a good price
  10. O

    Fernox DS40 through HW cylinder coil safe?

    You are ok to put chemical in aslong as its not a primatic cylinder and you are sure its an indirect coil, if you have a 3 way valve it wont be primatic as will be a fully pumped system, which isnt compatable with a primatic Putting it in will not cure your sludge problem, it may help with...
  11. O

    What pipe?

    Most likely to be 3/4 or 1/2 inch, looks like half inch from pic
  12. O

    Keston Celcius 25 HW fault causing vibrations

    Absaloutly awful awful awful boiler, doesnt help with your fault but thought i would let you know, also make sure your twin flue is MUPVC and not PVC like loads
  13. O

    Check Valves

    Also if your mixer passes, it can run back up into cold water tank and cause it to overflow
  14. O

    COPPER OLIVES N BRASS OLIVES

    I nearly always put PTFE around the olive, due to once a long time ago when i had around 6 leaks on about 6 joints, i was young and thought you had to get the stillies out for 10mm comp, well not that bad but in the end took them all apart and PTFE'd all ok, so ever since i do it 1st as someone...
  15. O

    Worcester 24CDi - burner cuts out

    When the hot water tap is running and it goes cold, does the red hot water light on the front of the boiler stay on or go off, if it goes off its most likely you diaphragm not a blocked plate
  16. O

    Check Valves

    Yes it is good practice to do this, and no you wouldnt be able to clear the air lock that way from a tap with check valves on
  17. O

    2 pipe central heating system

    First of all, yes you can split it into as many loop or zones as you like To add more radiators the boiler needs to be capable e.g. KW/ BTU If you mean can you tee into 15mm and add another rad, its not ideal, a lot of the time it works, but there is a calculation to work it out before...
  18. O

    Britony combi se 80

    He did tell you British Gas and at max you would of paid £399 put prob less, and trust me if you do repairs alot, on all boilers, you have experiance on Chaffs as they are cheap nasty things, that always break down
  19. O

    Britony combi se 80

    £360 on this hunk of junk, in car terms thats what they call a Write Off, as Agile said ign related you need an RGI, also i advise you use one for any boiler work carried out
  20. O

    Alpha cb28

    Yes replace boiler Alpha are a budget boiler, with expensive parts fit a vaillant, worcester, ATAG, Veissman etc etc