  1. HootingOwl

    Power flush required yes or no?

    What boiler have you had installed? Some manufacturers will use any excuse to shirk the warranty and some boilers react badly to dirty systems.
  2. HootingOwl

    Which? finds all boiler services sub-standard or dangerous

    Given that Which? consistently give Worcester as best buy rating, I would question their impartiality and judgement. As for gas hissing out into the room, well, what happens when you put the gas hob on...heavens above, gas hissing out into the room before it ignites! A curry fart is far more...
  3. HootingOwl

    Boiler Replacement

    Repair the profiles and keep them running. When they can no longer be mended, then a regular boiler is your best bet. The probem with free quotes is that the advice is sometimes worth what you paid for it.
  4. HootingOwl

    How can we avoid raising wet room base when there is limited space for the fall on the waste pipe?

    So you are doing a DIY wetroom on a timber joisted floor. I salute your bravery. A picture would help...
  5. HootingOwl

    Power flush required yes or no?

    The water was clean on the install I did this week. I put the powerflush on it and got a load of filth out of the radiators. Powerflush takes best part of a day to do properly. Ask for a reduction in the labour charge if he isn't going to do the flush.
  6. HootingOwl

    New Boiler (Heat only) for use with a Thermal Store (Kingspan Flowmax)

    Look on Ebay for someone selling an Ideal Classic cast iron boiler. Against building regs but far more environmentally responsible than fitting a modern shytebox that will not be efficient on a thermal store. If you must have a new boier then get the pump overrun wired up no matter what the...
  7. HootingOwl

    Bristan Artisan Evo - any experiences ?

    Digital shower = digital shyte Make sure it has a long warranty. I have seem a lot of busted processing units on digital showers and they are expensive to replace.
  8. HootingOwl

    System boiler without cylinder?

    Oh god give me strength
  9. HootingOwl

    Rented property - no room thermostat

    I suspect that the OP will be moving to a new flat come renewal time.
  10. HootingOwl

    biasi boiler faults

    Biasi Because It's A Shyte Appliance And what does the installer have to say about the turd they hung on the wall for you? Or was it an impulse buy at screwfix?
  11. HootingOwl

    Flow problem with new Worcester 38 CDi flow rates

    Oh dear. Wrong boiler. The trouble is that they are Worcester accredited which means they will only look at Worcester products. In your case, there was not enough clearance for a WORCESTER boiler and the cylinder. But a different manufacturer would have had a boiler that would do the job...
  12. HootingOwl

    Identify brand of radiator from logo & unusual leak help needed.

    It's a Heatline radiator. The DD is for Demir Dokum which is the Turkish company that manufacturers Heatline products. Now part of Vaillant Group
  13. HootingOwl

    Long history of vile practices by Surrey men (warning: Plumbing and gas)

    Nearly 1 in 4 were rogues...meaning more than 75% were honest and truthful and didn't put a foot wrong.
  14. HootingOwl

    Where can I get one of these?

    They come with the radiator valve. Got about fifty of them in the scrap bin....
  15. HootingOwl

    McAlpine 110mm Flexi BTW Pan Connector WC-F21R - should I use Plumbers mate?

    On no account should you use plumbers mait on one of these.
  16. HootingOwl

    Concealed Cistern Advice

    Find out what make of flush valve and fill valve are in the cistern. It may be an unknown brand and spares may be a problem
  17. HootingOwl

    Removal of hydronic plinth heater

    Don't join the pipes together. Just cap each pipe off witb a stop end.
  18. HootingOwl

    Combi boiler and water flow

    Whoever fitted the combi should have warned you about this. You need to look at the cold water wain serving your house. Insufficient flow rate to support both taps open at the same time.
  19. HootingOwl

    Viessmann Boiler questions

    I would take the viessmann over the worcsster. And i would fit a magnaclean. Powerflush depends on how filthy the existing system is and may not be needed.
  20. HootingOwl

    Waste pipe fall

    I read this as the OP wanting to put a 4 inch soil pipe under the floor. I would be investigating how easy it would be to install a new soil stack on the other side of the house.