Search results

  1. S

    Underfloor Heating - Help needed!

    Best and cheapest don't go together
  2. S

    Why internal combi expansion bladder fails?

    The orientation of the expansion vessels Water Connection should be downwards to avoid risk of sediment ingress or other debris from the system. Some provision for the prevention of air ingress into the vessel must also be made as this will degrade the vessel very quickly...
  3. S

    Why internal combi expansion bladder fails?

    That unit is for hot water Heating expansion units are red It's also fitted upside down the air gap should be at the top
  4. S

    DHW from Boilermate 2000

    What is the temperature of the hot water it should be approximately 60deg C
  5. S

    Oxy Pilot spark electrode

    That's about the most sensible thing you have posted
  6. S

    Oxy Pilot spark electrode

    It amazes me that anyone would even consider wasting time replying to a wind up.
  7. S

    Vaillant EcoTec 24 Pressure Issue

    Did you shut the valves off fully after topping up the pressure.
  8. S

    Main Eco Elite 30 pressure probs

    Oh dear leak sealer will block the main heat exchanger and plate heat exchanger you need to try and flush it out asap How many radiators are on the system
  9. S

    Baxi Combi Issues - strange happenings!!

    Has it had a proper service in the last 4 years has the expansion vessel air pressure been checked.
  10. S

    Combi Boiler rear pipe connections?

    Obviously your not
  11. S

    Unvented expansion vessel - unqualified engineer?

    If you e mail gas safe with your details for un vented they will add it to your card and add it to gas safe register.
  12. S

    what flux do you prefer?

    Copper Mate
  13. S

    Come & Have A Dig At The O.P (mega banter thread)

    Both parts have fibre washers you can order them from a spares specialist
  14. S

    Come & Have A Dig At The O.P (mega banter thread)

    We are all waiting with baited breath to see what conclusion you come to Tony
  15. S

    Hot water but no central heating - Ideal Logic 24

    Push the override on the programmer to switch it on
  16. S

    Hot water but no central heating - Ideal Logic 24

    The programmer to the right of the boiler needs to be on for it to work
  17. S

    Vaillant Ecotec Pro 28 Water only Lukewarm, HELP!

    And if you don't pay you pay
  18. S

    Main 24he not firing on heating or hot water

    Have you checked for power to fan is fan working
  19. S

    Speedfit problem.

    If you pull the locking ring out of the fitting then you will be able to pull the insert out Are the speedfit valves suitable for hot water as not all are
  20. S

    New shower will only work with shower head on floor

    Yes it is the same pump that is very close to the trade price that I pay Pumps should be fitted at the base of the hot water cylinder to prevent air being drawn into the pump on the hot suction side The cold supply should connect to the cold water tank on the side furthest from the ball valve to...
Back