    Honeywell zone valve

    A 28mm valve is far more likely to be used on a heating zone than a gravity one nowadays.
  2. T

    Reverse circulation in 2 zones installation

    No Need to pipe to boiler. It will be fine into return after last rad.
  3. T

    Riello burner motor not starting

    If you do not have a multi meter, you could wire a fly lead direct to burner to test. If you have tried the motor and control box the fault is on the controls. The easy solution is a voltmeter as pointed out already.
  4. T

    Honeywell zone valve

    28mm valves have 6 wire head as standard.
  5. T

    Trianco TRG 45 Thermostat

    90% of plumbers will not have a clue. It is however an easy task. Trace the route of the capillary and remove the two top screws securing the side panel, and lean it to the side Isolate the electric supply and remove spade terminals on stat. Remove any split pin or plastic bush retainer and...
  6. T

    Trianco TRG80 - fire keeps dying

    $hite fuel again. Anthracite should be black and shiny. I have seen these boilers slumber for 3 days with no heating demand. In the 1980,s , In an effort to save money " Coalflow Pearls" were introduced by the NCB for the Miners fuel allowance. Despite fitting additional stats and a kindling...
  7. T

    Add controls to Oil boiler

    That is unusual are you sure But if that is how it is piped you will have no problem fitting a stat.
  8. T

    Add controls to Oil boiler

    If you can switch the boiler only on to get hot water and both on for heating there should be no problem.
  9. T

    Worcester greenstar heatslave external 25/32

    He is hardly an engineer if he cannot use a multimeter Check the flow switch is not sticking !
  10. T

    Rayburn Royal going out

    Move the phial to a cooler position and see what happens. Temporally !!!
  11. T

    Plumbing GENIUS required

    What do you think oil pumps and tanks are made from.
  12. T

    Plumbing GENIUS required

    If you have a remote acting valve fitted already. Just swap it for a 1/4" lever valve as its only purpose will be for maintenance purposses.
  13. T

    riello burner issue

    Yes with a firm grip on shaft,
  14. T

    riello burner issue

    Pump should turn easily by finger pressure.
  15. T

    cleaning the inside of a riello oil burner

    fit a new nozzle. as for algae... I have never seen any in 40 + years on the tools.
  16. T

    Trianco TRG80 - fire keeps dying

    Are all your flue ways clear on boiler.