    Worcester Heatslave 20/25 fan keeps running

    The slave tank should be fully heated PRIOR to running a bath
  2. T

    Worcester Heatslave 20/25 fan keeps running

    If you want to retain a post purge to prevent smells. I have a P P unit removed from a leaking boiler you can have for a sensible price, I have retired so no use to me. The diverter fails to H W supply ie No Heating.
  3. T

    Worcester Heatslave 20/25 fan keeps running

    The easy way to isolate the post purge is to simply put the motor wire into the satronic base motor terminal and connect the wires to PPU together in the now free connector. Live feed to PPU should be made safe.
  4. T

    BSA Hotspur Oil Boiler

    I watched the video again .......... That Kero looks suspiciously like H2O. If the tank is same vintage as boiler and recent weather is taken into consideration!! Check OCV filter and whilst removed run a few pints into clear bottles. Or dip tank with water paste.
  5. T

    Back boiler won't fire up - faulty controller?

    I would guess a trapped melted wire,
  6. T

    BSA Hotspur Oil Boiler

    The spark should strike the flame ring not the grille. It was normal for a hole to be eroded at this point,. Repair clips were used. the spark should be crisp and blue like an arc weld
  7. T

    Sink drain pulling vaccum on boiler condensate trap

    Should be an air break to prevent it.
  8. T

    Multifuel stove/central heating

    Two stats wired in series one make on temp rise other break on rise.
  9. T

    Worcester Danesmoor 26/32 oil boiler lockout problems

    Have you checked that the FZ is not seeing false flame during prepurge.
  10. T

    oil boiler triping

    The white smoke is soot/carbon burning off. It should slowly stop as deposits burn. Have you cleaned the baffles and heat exchanger Just noticed you have tagged onto an old thread Stick to your original post.
  11. T

    Worcester danesmoor 15/19

    It is removable. BUT is there another one as that looks like the Hot water valve
  12. T

    Worcester danesmoor 15/19

    If there is a\ dimple on the cover the head is removable.
  13. T

    Worcester danesmoor 15/19

    what make valve is it.?
  14. T

    Worcester danesmoor 15/19

    Near pump or in cyl cupboard usually. No fixed place
  15. T

    Grant Votex Oil Boiler

    Which model. Usually caused by low pressure and air in system
  16. T

    Worcester boiler black smoke after service

    If nozzle is correct size and oil pressure ok it must need more air. slowly open air shutter until no visible smoke is seen..
  17. T

    Tiger loop kit fittings

    1/4" x 1/4 flexy oil line nipple and 1/4 F I x 10mm . The flexy lines should be connected to the pump
  18. T

    Worcester Danesmoor 26/32 oil boiler lockout problems

    Are you using an auto ranging multimeter 1'956or 2k is fine. was initial reading.023 meg 230k
  19. T

    Bentone st 108 burner bolted to a Trianco boiler

    Considering the price of fuel It would be a good move to PAY someone with test equipment to check the settings and combustion. Are you using new nozzles or ones that have been cleaned??
  20. T

    Worcester Danesmoor 26/32 oil boiler lockout problems

    Check the coil resistance immediately after lockout