    Bentone st 108 burner bolted to a Trianco boiler

    Try dropping oil pressure to 8 bar and reducing air shutter for clean burning. the soot is unburnt fuel probably caused by impingement..
  2. T

    Central Heating flow problem?

    Less load is less gas What do you expect to happen.
  3. T

    Central heating C Plan miss behaving but can't work out what is going on.

    Are both pumps running and M/V s open when there is a demand?
  4. T

    Bentone st 108 burner bolted to a Trianco boiler

    '85 @ 12 bar is about 40 kw input. so waaaay over gassed. check burner rating on data plate .head settings etc. could be wrong burner. what smoke no is it ? FGA readings ????
  5. T

    Central heating C Plan miss behaving but can't work out what is going on.

    Is there a relay to allow the boiler and pumps to run independently.
  6. T

    Worcester Danesmoor 26/32 oil boiler lockout problems

    He means checking if the coil is producing a magnetic Field. A steel screwdriver will hang for a few secs. Coil resistance is a few K ohm.
  7. T

    Bentone st 108 burner bolted to a Trianco boiler

    28 or 35 sec fuel, boiler model and output and nozzle sizes . FGA readings
  8. T

    Riello burner tripping rccb

    Un plug the burner to eliminate external faults
  9. T

    Riello burner tripping rccb

    RDB burner then, At which part of the ignition cycle does it trip? Unplug the burner from the control panel to check if wiring or burner fault.
  10. T

    Riello burner tripping rccb

    Which boiler do you have??
  11. T

    Riello Oil Burner RDB2.2

    Remove the oil pump and check for tight spots when rotated also the motor.
  12. T

    Leaking Roof by Chimney

    If it was watertight before the new roof and leadwork then why should it need a tray now. I have Fitted liners to and relined with " Isokearn" hundreds of flues. I have never seen a tray fitted.
  13. T

    Worcester greenstar utility 18/25 oil intermittent spark

    The EBI can sometimes give intermittent spark. I usually fit a new one from van stock and see if it cures the problem !
  14. T

    Worcester greenstar utility 18/25 oil intermittent spark

    are you keeping the cell in the dark,
  15. T

    Boiler not firing - which valve?

    Try both of them. I love to see a well maintained boiler.
  16. T

    Do I need a new electric CU for (Rental) EICR? (Ed.)

    I was under the impression that an EICR Was like a gas safety inspection, ie A report on the installation as found at the time of inspection Not a pass or fail,
  17. T

    Leaking Roof by Chimney

    Obviously not !!! As there is water ingression !!