Search results

  1. T1GERIII

    Pyronix Dual Tech PIR changed battery nor saying restore required

    Didn’t happen to lose the front tamper spring by accident? Done that before the pesky thing flew off without me noticing
  2. T1GERIII

    Texecom Premier Elite fault light, no power to key pad

    Engineer utilities > confirm devices > network 1 What is displayed in there?
  3. T1GERIII

    Remove alarm - Panel Marked ZX 901

    Probably when it was installed! Haha Open panel disconnect battery and isolate mains power. I’d imagine your external bell is already dead and won’t cause any issue
  4. T1GERIII

    Pyronix Enforcer beeps for 7 seconds before setting

    OP is referring to Exit Route tone so hallway activating upon exit route. Only solution to this is as mentioned silent the exit tone, get the app or a keyfob-we and arm from outside save using the keypad and hearing the tones
  5. T1GERIII

    Extending alarm cable

    Alarm junction box
  6. T1GERIII

    Pyronix euro46 fullset issue

    Area A exit mode set to final exit?
  7. T1GERIII

    Pyronix Alarm Help

    Really simple to back door the system and gain engineer access no re-programming required PM’d you
  8. T1GERIII

    texecom firmware

    If you have no issues with the alarm I would leave it, flashing the firmware could possibly cause you more headaches. Various texecom wireless sensors, depends on the environment its going, how sensitive you want that sensor, type of detection that could prevent false alarms etc…
  9. T1GERIII

    Which replacement wired PIR please?

    You’re correct in your assumption, and no it doesn’t matter which way round you wire the pairs as long as the blue and yellow are used in NC, green and white as tamper
  10. T1GERIII

    Pyronix euro46

    Keypad 0 zones are 73 and 74
  11. T1GERIII

    How to Disable Texecom Premier Elite 24 Alarm prior to building work

    Mains off , disconnect standby battery. Bell will sound off for 20mins then stop.
  12. T1GERIII

    Pyronix PIR identification

    Pyronix KX15DQ, Not pet friendly
  13. T1GERIII

    New wireless alarm: Visonic, Pyronix, Texecom or ???

    Completely false. 100% pyronix easiest systems to install and set up
  14. T1GERIII

    Scantronic 9448 Very Odd Error

    Tried default codes? 0>7890
  15. T1GERIII

    Ring Doorbell Alternative

    Eufy doorbell no subscription
  16. T1GERIII

    Scantronic 9448+ all brands of sirens compatible?

    Any brand will work; recommend pyronix delta bell easy to connect
  17. T1GERIII

    pyronix manual and Qs

    Change engineer code- Enter engineer code, press no until it says change codes press yes on that Then yes again Followed by no until it says change engineer code press yes Press C to clear existing Enter new code followed by yes Press no until it shows CHANGE CODES again. press A to save and exit
  18. T1GERIII

    pyronix manual and Qs

    Change master code - press D , enter your master code press no until it asks to change codes or edit users. Press yes on that then no until it says change master code. Press the C button to clear existing and then type New code followed by the yes button. Press no until it says change codes/edit...
  19. T1GERIII

    Changed WIFI router for hikvision -how to reconnect so hikvision app works?

    As Sparky said, wrong IP range possibly gateway set for old router IP on a different range. Enable dhcp then disable.
Back
Top