    Which heat-only boiler?

    Any rnd dept that design vessel at the back needs to go out with the in house engineers when replacing one when it's in an awkward position etc maybe they would think twice!!!
  2. H

    Which heat-only boiler?

    Not keen on the combi set up vessel behind boiler is not a good move and valves break off easy after a while as the brass bit behind plastic lever, the rapid is ok but only 6l vessel where there seems to be room for an 8l. Heat only very good as the system as you can locate the vessel in airing...
  3. H

    Ideal boiler noise \ normal?

    Can't here anything as the link is unable to download if in doubt call ideal what boiler model is it???
  4. H

    Logic 24 losing pressure

    Yes it will happen again due to down firing Ali heat exchanges they are weak, a bit like the glowworm flexicom, had same issues Good luck
  5. H

    Which heat-only boiler?

    Intergas all the way for heat only, not sure what there tech/support is like but good bit of kit as it's very simple design and heat ex is like 22mm pipe so can't see it blocking up Good luck
  6. H

    Vaillant internal ABV question - broken?

    What size is flow and return pipe work, on a 37kw I'd be expecting 28mm min reducing to suite system design etc, is it range rated via d0 ? The temp diffs between flow and return should be 20oc , the auto bypass really protects the hydrolic block but also a external bypass maybe required if...
  7. H

    Ideal ICOS HE24 gas Boiler - sometimes makes a loud noise when stops heating

    Dp I worked for ideal for nearly 2 years so yes I no the boiler very well! Very straightforward but very poor product!! You enjoying cracking one out on them
  8. H

    Ideal ICOS HE24 gas Boiler - sometimes makes a loud noise when stops heating

    Could be a number of issues i.e. Is there a bypass on system, is the noise only when it's been running and reaching temp, usually if pump or fan it's noise all the time etc. Best thing to do is video the issue on your phone then either call a local engineer or call ideal as a fixed price repair...
  9. H

    New Worcester Boiler fitted

    Sorry I thought that was a thank you
  10. H

    Vaillant boiler dropping pressure

    Could have a bit of dirt in pressure sensor giving incorrect reading and you top up system which may have over pressured and opened prv. Get your installer back to have a look
  11. H

    New Worcester Boiler fitted

    Get your installer to do a water sample test and send it via either Fernox/adey/sentinel there the company that make chemicals to keep/clean heating systems, you then get a certificate to confirm either way! Good luck but give your installer a chance maybe he has to come back to clean system
  12. H

    HE24 Vibrating Boiler Noise

    Gas valve get it replaced when on low flame sounds like solinoid chattering,get a gas safe engineer to sort it or pay ideal a fixed price repair
  13. H

    Baxi Barcelona - explosive ignition

    Gas valve will be letting by
  14. H

    Baxi Barcelona - explosive ignition

    Gas likely to be letting by =noise or flue issue Simple when you change the same bits time after time you got to look out side the box
  15. H

    Continous f75 error vs boiler replacement

    Has the pump been changed? Has the flow pipe got the rubber hose on it? Is the expansion vessel set point to much or not set up for system. When bg power flushed they may have dragged muck in boiler
  16. H

    Vaillant Thermocompact 637E Won't fire up

    Fan and aps! Check flue is sound, fairly straight forward job good luck
  17. H

    Vaillant Ecotec 937 Plus, no hot water

    If you press bottom left and top right buttons it will give a fault code in past, if gauge is on zero but you press the bottom left button it will say pressure. Lkely to be pressure sensor blocked,vessel flat,prv may need replacing. On the hot water side, either flow sensor not operating,hw...
  18. H

    Glow Worm Obsolete Boiler Valve Part

    Where are you based in the uk ? As far as i know you cant get them anymore
  19. H

    Fitting a Veissmann 100-W Heat Only

    Hi make sure you have got the correct output as on viessmann heat onlys you cant range rate the heating,unlike other brands,this will mean boiler will cycle alot and if over 24kw make sure its 28mm pipe min to allow heat transfer otherwise it will not sense on return thermistor. Good product but...
  20. H

    Vaillant Ecotec Plus - Pump overrun when restarting

    Hold up---- you say a combi but you have a y plan with zone valve,cylinder and tank. Also you set temp to 55 and it cuts out then that sounds to me like its doing its job,you need to up temp on heating to 66-70 oc then check operation Sounds like things dont add up