    Reverse Circulation when HW On

    On hw only, most return water will take the direct route from tee 2 to tee 1 but some will take the more complicated journey, backwards through the towel rail and forwards through every rad and check valve in the house. Probably not noticeable at rads but turn them all off bar one and you will...
  2. D

    Hot Water Running Out

    On those Center ones (I hate spelling it that way) the secondary return tees into the cold feed. There is a horizontal pipe behind the cylinder and the hoover hides where it goes to. Does it tee into the cold supply pipe?
  3. D

    Hot Water Running Out

    Is that a secondary return hidden behind the hoover?
  4. D

    Underfloor heating power cable

    It may be this one but if not there are several choices https://www.euroboilerparts.co.uk/puv-compatible-cable-for-grundfos-upm-pump-cable-fits-vaillant-0020221616-1823-p.asp
  5. D

    Can not find tap gland/cartridge in the right size

    https://www.tapmagician.co.uk/NSAboutIdentifyValve.aspx
  6. D

    Immersion troubleshooting - is there anything else I can test

    Live is fed to the immersion through the thermostat, then the incorporated overheat stat then the additional overheat thermostat. From what you say I think It is a new thermostat that you have fitted The additional overheat stat keeps tripping. Seems that this additional stat is tripping at a...
  7. D

    Removing arrestor

    I believe that no. is a 15mm compression so this would be your man https://www.screwfix.com/p/flomasta-compression-stop-ends-15mm-2-pack/65021 It could be that someone has removed the nut & olive & screwed the 1/2" thread directly into a female fitting in which case you can put ptfe around the...
  8. D

    Unpleasant smell in 2 bathrooms

    Will be ok as long as it doesn't droop down & back up again as this will collect condensation.
  9. D

    Removing arrestor

    Then plan A is certainly possible. If you have a combi boiler many manufacturers insist on a mini ev being fitted. It is often a failing ball valve that causes noise problems or a dripping 1/4 turn tap. You could try pump up ev to 1 bar then turn mains back on & see what pressure the ev is...
  10. D

    Pumped hot water loop alternative

    The lower fascia panel will pull off. Usually pull upwards to detach it from the lift off clips. This will give you much better access. You may have room for a second ball valve in the cistern but I have no idea how you think that would help.
  11. D

    Removing arrestor

    I would first of all Turn off water and open tap to release pressure. Attach compressor/foot pump/bike pump to shock arrestor and pump up to 3.5 bar. Turn water back on and see if problem has gone away. Check that your stop tap is open all the way and back 1/2 turn
  12. D

    Bath tap cartridges

    Usually not aa problem but sometimes they resist.
  13. D

    Bath tap cartridges

    Clean the seating before fitting the new ones and a smear of silicone grease never hurts. If they are not a common size, tapmagician has an 18 sheets of A4 list of dimensions to choose from.
  14. D

    Pumped hot water loop alternative

    You could always fit one of these, blended supply to wc and set it to about 20 degrees. Would draw mostly from the hot pipe till temperature achieved and then continue to fill cistern with mostly cold. https://www.screwfix.com/p/flomasta-thermostatic-mixing-valve-15mm/684fa This will be full of...
  15. D

    Hot water not coming through all outlets as hot - ASHP issue?

    Start with the easy exposed one. Run shower till body is hot, usually on left hand side. Run a not so hot tap. Cold water flowing through the shower will rapidly cool the LHS of this shower. If it is not this one then you will have to repeat by pulling the faceplate forward on the concealed...
  16. D

    Bath without a trap

    Is this internal or external?
  17. D

    Hot water not coming through all outlets as hot - ASHP issue?

    It will be a temperature controlled mixer so shower mixer not basin mixer. While running a not so hot tap you may hear something if you put your ear to temperature control knob. If they are exposed valves the temperature check by feel will be easy but if they are concealed and you can access the...
  18. D

    Hot water not coming through all outlets as hot - ASHP issue?

    Could be a faulty check valve on a shower. If you run one of your not so hot taps and then wander around and feel your shower valves is one of them particularly cold?
  19. D

    Is this drain hose plumbed incorrectly?

    Waste hose should go up to underside of worktop then back down to connection point in order to stop sink waste back-filling washing machine