  1. D

    Need extra heat!!

    To confirm that the K2 will do the job, buy a 350 watt electric heater for about £12 and put that in the room. If that & radiator now get the room toasty then the K2 will do it. If not it's get the man in time. Save you spending on the rad & then spending on another rad.
  2. D

    Replacement CH/HW programmer options

    If you search ebay for Grasslin timer there are loads for about £20 and you could just change the clock. Alternatively someting like Drayton programmer & change the whole thing. It is only 5 or 6 wires
  3. D

    Fitting a Surrey/York flange to a Hot Water Tank with a 3/4" outlet

    Sorry, didn't spot that. Photo not great & I thought I was looking at a male iron - 22mm screwed in. I suspect that your outlet is not 3/4 but is in fact 22mm compression. If this is the case then either cut flange in to cylinder or:
  4. D

    Fitting a Surrey/York flange to a Hot Water Tank with a 3/4" outlet

    Screwfix Warwick Male Flange ¾" (88212)
  5. D

    Water Pressure reducing valve

    From Reliance (RWC) datasheet Installation flexibility: can be installed in any orientation and is available in both hot and cold versions https://www.rwc.co.uk/rwcuk/wp-content/uploads/312-Compact-PRV-Spec-Sheet-04.pdf
  6. D

    Water Pressure reducing valve

    The instructions say that but......
  7. D

    Boiler overheats when only UFH is on

    boiler has a built in bypass and should not require an external one. If internal bypass has become restricted or blocked you could either check & clean internal one or fit an external
  8. D

    Baxi gas combo boiler 105he

    If your flue outlet is not full of ivy, this is going to require professional attention
  9. D

    Baxi gas combo boiler 105he

    I am not clear, does it fire or not?
  10. D

    Gas boiler diagnostics related question... can I ask it here?

    You can ask whatever question that you want. Just that the replies will be limited.
  11. D

    WB Greenstar 35HE high pressure problem

    So when you pumped up EV, did you check gauge? Still on zero? Probably not so drain to zero, inflate to .8, drain to zero etc etc. Alternatively leave drain off open while you inflate EV The ev should be at .8 with the gauge at zero, then re-fill system
  12. D

    Boiler losing pressure every day, replaced PRV, Gauge not showing high pressure

    As Terry says, leaking ht exchanger in boiler. The leak will vary with temperature so air slightly warmer, leak slightly worse. re-connect your condense, leave heating isolated and go & run yourself a nice hot bath. Should see a bit of pressure loss then (when it has cooled).
  13. D

    Boiler losing pressure every day, replaced PRV, Gauge not showing high pressure

    Sounds like it is the boiler. Sometimes it will leak when hot more than when cold. You can either, top up boiler to 1.5, isolate heating circuits, run hot tap for a while to get boiler hot and see what pressure you have lost or, turn boiler off, top up to 2.5, see if water continues to dribble...
  14. D

    Combi Heating Problem. How Water Fine!

    Have you perhaps closed off either the flow or return valves beneath boiler?
  15. D

    Ecotech - Pressure issues

    Choose a radiator that you can live without. Turn off both valves on the rad & drain the water out. Turn one valve back on & the air in the radiator can be your temporary EV untill engineer arrives. Sounds like your analogue gauge is blocked
  16. D

    Increasing flow rate from shower

    If both of your showers have 2m head, the reason for the difference in performance may be that 1 has more dirt in the filters than the other. Mira miniduo operates on minimum 1m head and I have used a few on low head applications and been pleased with performance. Not too dear either.