    Central heating not coming on

    Could be or perhaps ivy in flue or hole in aps tube.
  2. D

    Central heating not coming on

    Drawing a bit of hot water, the boiler fires. Turn off hot water ch continues to run. Problem with flue/APS, boiler turns on for ch, fan runs at 70%, not enough flow to trip APS. Draw HW, fan runs at 100%, Aps trips & boiler fires. No guarantee just the first area that I would be checking.
  3. D

    Hot water but no heating

    They don't normally operate the switch unless "thrown" open. In the manual position the switch is usually off. Of course he may have some bizarre make of valve.
  4. D

    Central heating not coming on

    I would check the microswitch on the diverter but more likely to be a air pressure switch related problem. Not really enough info to tell. Have you got ivy in your flue terminal?
  5. D

    Hot water but no heating

    Or roomstat or time clock or zone valve motor. Not sure that I understand this . You seem to be saying that CH works but everything else points to heating not working. Do I understand correctly that: HW OFF CH valve manually open Rads get hot
  6. D

    Odd underground pipe? Can anyone identify?

    My guess, and it is a guess, just badly made. When you cut it out it may be perfectly normal inside
  7. D

    Odd underground pipe? Can anyone identify?

    The flexi seal adaptor couplings with a jubilee clip come in a variety of sizes. Sure you will be able to find one that fits. https://www.flexseal.co.uk/assets/Data-Sheets-Folder/Flexseal-Adaptor-Couplings-Datasheet.pdf
  8. D

    Baxi 105e

    It is diverter valve not properly closing the heating circuit. It is a mechanical item so should be straightforward. You can buy a complete exchange refurbished valve for £45 if you can not see the problem.
  9. D

    3way heating and hot water issue

    Yes replacing the actuator head IF it is in fact the problem. It could still be cylinder stat, programmer or room stat. What I was saying, with valve manually opened, remove cylinder stat to keep hw &ch running pending test & replace failed component.
  10. D

    3way heating and hot water issue

    To keep it going just remove the cylinder stat from the cylinder
  11. D

    Hot water venting cold water header tank

    So nothing is connected to the coil in the cylinder?
  12. D

    Structural issue or slant shower base?

    Have you removed the shower door? Your video doesn't quite travel far enough to tell. Reason I ask is, the sealant hidden behind the door frame is a very important part to get right.
  13. D

    Ferroli Optimax HE31C

    Thanks Duz, now we are all hoping that we never need it!
  14. D

    Hot water venting cold water header tank

    Is your heating tank fed or sealed system?
  15. D

    Ferroli Optimax HE31C

    Can you put a copy on here? May be useful to someone
  16. D

    Ferroli Optimax HE31C

    Sorry, so it doesn't. I have this, not much but may help:
  17. D

    Ferroli Optimax HE31C

    If it is the Optimax HE 31C
  18. D

    Radiators not hot enough

    The boiler shuts down when it is up to temperature (Return is hot) so it is circulating around either the cylinder or the "easiest" rad and going back to boiler. Is it any better on heating only? Is there a rad that gets particularly hot? Is there a by-pass, perhaps in the airing cupboard?
  19. D

    keeps shorting

    While the power is OFF, remove the cover on the side of the pump and see how wet it is in there. If it has water over all the connections this will cause the trip to blow. Unless water can have dripped in there from above, tracked along the cable, this will be a new pump.