Search results

  1. easyflow

    Potterton Puma 80e / 90e Repair / Replace?

    Sounds like the dirt and sludge is killing your boiler, I would replace after a thorough flushing of the system.
  2. easyflow

    biasi riva no hot water

    Sounds like the diverter valve.s jammed.
  3. easyflow

    Quick question I'm sure you'll know the answer to!

    Are the lock shields other side of the rads fully open ???
  4. easyflow

    glowworm 30 cxi

    PCB, Had two with identical faults 24cxi and 30cxi, new pcb about £120/150 unless you go for the exchange about £60/70. Takes about 2 mins to change, you will probably get E13 display to start with and then after a few moments it will clear itself and fire up, if not turn to reset and off you go.
  5. easyflow

    Condensing boiler exemption

    Dont think you said what boiler is hanging on your wall at the moment. Tell us make and model and its highly likely the repairs would be much cheaper than replacing if you get the right person in.
  6. easyflow

    New Boiler needed?

    Always amazes me how people condemn a boiler (ideal 30 he) in this case because its had a few problems, did you ever consider it may be the cause of the installer, lack of maintenance, engineers who dont have a clue, do you really think your new worcester/valliant etc is going to fair better...
  7. easyflow

    Is this normal for a bath?

    you can either build a cradle and slot the bath into it or batton the back wall to support the back of the bath and strut the front side to support the the front side which will help fitting the side panel, without the timber supports that acrylic bath will always have movement, dont think the...
  8. easyflow

    Is this normal for a bath?

    A couple of angle brackets normally fix to the bath timber frame then sunk into the wall before tileing, the legs of the bath have holes in them to screw to the floor, but a steel bath would have been better.
  9. easyflow

    Help ! Corroded heat exchanger, boiler condemned

    You need a good inhibitor in the heating system and a lime beater on the mains side when the new boiler is installed.
  10. easyflow

    Inhibitor

    Got a bit more info Micky.
  11. easyflow

    Vaillant combi boiler CH but no hot water

    Cant say without a photo but sounds like it.
  12. easyflow

    Boiler Recommendations Needed

    Pick any main brand boiler you want and if its installed properly, your guess will be as good as anyones.
  13. easyflow

    Vaillant combi boiler CH but no hot water

    You must have left the cold mains feed to the boiler closed, open valve and all will be ok.
  14. easyflow

    Cold Radiators.... Running out of ideas

    Had a similar problem with an old system before christmas, found a major blockage cut some 22mm out but not much better, changed pump and flushed system still no good, pulled some floor boards and turns out the system was running on one pipe. Converted to two pipe system and all rads came up a...
  15. easyflow

    how to add inhibitor to normal vented ch system (f/e tank)

    Drain enough water from FnE so that the inhibitor gets into rads and dosnt just sit in FnE tank, you can turn off water from mains if you like but you wont have any mains water in the rest of the house while your adding the inhibitor.
  16. easyflow

    baxi 105e no hot water again!

    Pump spindle might be turning but what about the impeller behind the spindle ? Would remove pump head and test off the boiler.
  17. easyflow

    Help increasing boiler water pressure

    Turn the mains off by the stop cock and change the ballafix, the other side of the flexi has a check valve so very little or no water will leak from the check valve.
  18. easyflow

    central heating pump problems

    Its fine on 3, change pump head if it worries you.
Back