  1. 333rocky333

    Rewiring Lawn Mower - Power Switch

    Though you may find the ferrules also stiffen the cable enough to allow the cable to push into the terminals
  2. 333rocky333

    Mains indicator LEDs

    Bg socket
  3. 333rocky333

    Mains indicator LEDs

    Broke one open and this is inside, looks like a neon, If you want John give us a few weeks and I may have a few more, if you want them I could post them
  4. 333rocky333

    Mains indicator LEDs

    Looking at there Tech spec on TLC seems they still use neons, will break one open soon get some pics
  5. 333rocky333

    Mains indicator LEDs

    You asked similar in 2017 and at the time mk still sold there neons, maybe now they also have an led version. It may be easier to find a brand that does use leds and remove from an accessory. We replace a lot of damaged bg sockets, they have a light on. Next time I do one I will break open...
  6. 333rocky333

    Test equipment

    Having a clear out. Have listed a kewtech KT71 PAT tester on ebay if anyones interested, going cheap, also soon to list a metrel MI 3125 multifunction tester, any interest message me. Also some older test gear, working as far as I know but no time to test it all really, including another...
  7. 333rocky333

    Correctly wired LED dimmer?

    The dimmers shown and the one you intend purchasing appear to be 60w minimum load. Your 6 spotlights are unlikely to meet that requirement unless for led loads the dimmer rating is different.
  8. 333rocky333

    Odd GU10 to GU10 adapter

    Google LONG NECK Gu10 you can get 6000k ones
  9. 333rocky333

    Do cables wear out if used too much?

    No it's in free air, its all cracked and when touched just crumbles, the outlets are on the main ceiling slab and they dangle down to the false ceiling 600mm lower. Because of the nature of the premises the temperatures a tad average than normal though nothing drastic. The cable is well marked...
  10. 333rocky333

    Do cables wear out if used too much?

    Not sure what's happened here, cables only a few years old and most of the flexes from the plugs to the lights within the ceiling Void just crumbling away
  11. 2024

    2024

  12. Screenshot_20240324_203700_Gallery.jpg

    Screenshot_20240324_203700_Gallery.jpg

  13. Screenshot_20240324_203646_Gallery.jpg

    Screenshot_20240324_203646_Gallery.jpg

  14. 333rocky333

    High Integrety CU - Internal cabling

    I have mentioned them a few times :giggle: I recently sheared my modulo head on my torque driver the maker replaced it free and give me some surprising news relating to modulo head screws in dist boards, if your interested i will try and pm it to you as i dont want to publicly announce it
  15. 333rocky333

    ring doorbell

    Yes all correct thats what i was seing and the back is the same with the same label, thanks, though i find it odd why Ring only seem to sell a Dc transformer which seems to be DC with unmarked spade ends when tested with a meter., it also suggests putting the seemingly unmarked positive...
  16. 333rocky333

    1.5" fluorescent tube fittings

    Do not really underrstand the question . Tri phosphor tubes would be T8 and a 1.5 inch tube would be T12, both of these use the SAME bipin fitment, unless your fittings are from the 1960's. where you may have needed a BC to Bipin adaptor. Whether T8 works in the T12 is down to the control...
  17. 333rocky333

    ring doorbell

    I have i believe a ring doorbell 5 i have lost the book, scanning internet it seems i need an AC transformer, however the transformer i bought is a Ring plug in job, but it appears to be DC . Bit confused what is right to do as Ring do not seem to sell an AC version. Obviously i know i could...
  18. 333rocky333

    Told I need to have Ze checked, an R1+R2 test, and possibly downrate a 40A fuse to 32A - any way to save money here?

    Could he have meant the risk of injury by electricution to the client is less, due to having the rcd protection. With a high Ze an rcd protected circuit is more likely to go off under fault than a mcb protected circuit, would it not
  19. 333rocky333

    Vent Axia SELV 12, Ceiling v wall mount?

    Not sure if its true but i always thought, back in the day that they had different bearings due to the orientation