Search results

  1. G

    Distribute Now TV in HD to 2+ remote TVs

    I currently use the sky + HD rf out to distribute to about 3 TVs in total. Sky costs have gone up so much. I am considering dropping it, and replacing with Now TV which is far more pay as you use orientated. Anyway, one issue, is that because the Sky+HD box had an RF output with a modulated...
  2. G

    Wall cavity arrangement under Large Aperture Sliding Door Track

    Thanks for replies. So, the door track is about 180mm excl. a minimalsit 10mm cill overhang on the external. So what we have decided on today, which hopefully solves, is lay a second course of bricks against the outer leaf on their edges. So 100mm outer, 65mm+10mm mortar for bricks on edge...
  3. G

    Possible land drain in corner of trench fill foundation pit

    Thanks for comments. Kind of wish I had of just told builder to cut in the upstream and divert into the soakaway and then crack on.. but I could not 100% say what drainage it actually is! He spoke with Building Regs and BR wanted it repaired and lintel and padstone over which has meant more...
  4. G

    Possible land drain in corner of trench fill foundation pit

    What is the best approach for something like this? There is no water running in it presently and it appears dry. It is dry weather here today though. It is cutting diagonally across our rear garden, I pushed a rod up stream and got to 10M which is just over the neighbours rear garden boundary...
  5. G

    Wall cavity arrangement under Large Aperture Sliding Door Track

    Ok. So I tried to sketch out the arrangements as I understand them and from helpful suggestions. The conventional arrangement with the cavity closer both my builder and window installer don't think is viable at all, so just a starting reference for me to understand versus other options. Have I...
  6. G

    Wall cavity arrangement under Large Aperture Sliding Door Track

    Thanks for suggestions. Ok, so that is a variation of what I read in an older Diynot post, so in your suggestion you push the cavity closer to mimimise the unsupported insulation overhang in the cavity? Still relies on fixings for the door track not falling on the 30mm to 50mm cavity width, I...
  7. G

    Wall cavity arrangement under Large Aperture Sliding Door Track

    My designs, as critiqued on here regarding flat roof / false pitch design, are light on detail. In the design it is shown that cavity closers used for windows and doors including at the base of the large sliding doors. Approx 4.2M aperture. The builder who has just started, said often that...