  1. Y

    Electric Shower Installation

    The shower force 1500xt runs off a fuse spur, a normal electric shower doesn’t. You may have an old shower supply in the loft, if not a new supply will be needed from your consumer unit, also rcd/rcbo protection will be needed. If you have an old style fuse board, some of these are not...
  2. Y

    Novice decommissioning Honeywell alarm

    the sounder will sound for 15-20mins, need ladders to stop/remove battery. disconnect all the rest as your going, remove the fuse from the unswitched spur you're pointing at first to remove panel supply
  3. Y

    Novice decommissioning Honeywell alarm

    You need to find the source of the twin and earth cable (grey) and isolate there, normally an unswitched spur and then the panel is totally isolated
  4. Y

    connecting CPC between socket and light circuit

    i read it as a dual mount box, with 1x single socket and 1x 5a socket fitted or something similar fed fom the lighting circuit
  5. Y

    One gang socket with USB

    Are you serious?? You do know usb power output generally is 5v and that the sockets have a built in power supply? Connecting a usb to 230v would kill the thermostat and possibly you
  6. Y

    Imperial mains isolator 3 phase and neutral 200A

    Check if it has the asbestos rope seal and flash guards removed before selling it
  7. Y

    BT distribution point removal

    How do you think there going to get a cable into the office block when you've deliberately cut their cables off and buried them? The intake could be in the basement with no way up to the offices now The dp is openreach property and is possibly the only route for the cabling and cutting it off...
  8. Y

    MK2056 Base with neon - no instructions

    Just because you ‘can’ doesn’t mean you have too. Gven that a grey conductor is available and is the correct core to sleeve blue, why would you not use it?
  9. Y

    MK2056 Base with neon - no instructions

    Black hasn’t been neutral since 2006, in a 3c and earth you use the grey as neutral sleeved blue Apart from that then you’ll be good to go
  10. Y

    Economy 7

    it turns on the off peak cu at the time set by the dno via the switch live to the contactor coil
  11. Y

    Power outlet for wall mounted speaker

    could use architrave box and blank hidden behind the speaker if fed from a centrally located switch spur?
  12. Y

    Upgrade garage lighting

    It's completely irrelevant how often i post on the forum, but thanks for breaking it down into monthly totals. I work full time and have a home life, forums come down the pecking order of priorities and spending all day building up my post count is not important to me. And i'll remind you of...
  13. Y

    Upgrade garage lighting

    Obnoxious people don’t offer there wealth of experience and knowledge for free on a weekend do they? I also wouldn’t call 7 years as a contributor as new, which incidentally is longer than you’ve been a member. Perhaps you should have contributed constructively to the thread instead of jumping...
  14. Y

    Wet electrical switch

    damm i was looking into buying a bonemeal 1g 1way switch as well, think ill stick to the traditional self extinguishing plastic now for safety.
  15. Y

    Cooker Hood has plug at the end, though my connection is hardwired? Help!

    this then needs sleeving and connecting to the earth terminal in the joint box so:_ 1. chop plug off cooker hood 2. fit joint box onto grey cable using line, neutral and earth into the respectable terminals 3.strip flex and terminate cores into the joint box matching the colours to the...
  16. Y

    Wet electrical switch

    please explain how water can damage electrical cables, if thats the case then why don't copper pipes collapse when filled with water?? best solution:- find source of water and repair check earthing to switch is continuous and can read 230v between earth and live for peace of mind simply replace...
  17. Y

    Upgrade garage lighting

    errrm
  18. Y

    Upgrade garage lighting

    No! Junction box is also the lazy and unnecessary way of wiring, its a brand new install! simply pull the existing cable back to the new 1st light position and then install new cable to the 2nd,3rd etc position. except some fittings have high inrush startup and can trip mcbs
  19. Y

    Making extensions for workstations + front door motion sensor light

    what exactly do you think the motion sensor is going to do plugged into a socket?
  20. Y

    Question on a landing light wiring

    instead of cutting random cables and hoping for the best, you need to trace a permanent live,neutral and earth drop the rose from the upstairs lights and test, if no perm live then find the upstairs joint box and test then take a twin and earth to new attic switch and then a twin and earth to...