  1. Y

    mains earth feed

    unlikly to be a duct so will be a struggle. It depends on tails size for earth size. If service fuse is 80/100 amp then 25mm tails 16mm earth required, if 60 amp fuse then 16mm tails 10mm earth will suffice however 25mm tails is the norm nowadays. you may need to replace tails as old...
  2. Y

    Replacing a loop in ceiling rose with a junction box

    as long as the jb is kept accessable then yes you would need to notify as your modifying the circuit however that is your choice this is a diy forum not the council police and who's to know
  3. Y

    230v Bathroom Fan - OK for shower area?

    you may want to consider installing a condensation trap on the ducting as well. the mi may recommend this also. As for earthing the ducting as taylortwocities says, that is complete tosh as you will be modifing the cabling you will need rcd/rcbo protection on the lighting supply also a fan...
  4. Y

    2 gang bridging power

    In order to use the switch to feed another light fitting you will also need another twin and earth taking to the switch from the pendent then connect up as follows :- brown of 3 core to live in on pendent black of 3 core to switch live on pendent with brown sleeving fitted grey of 3 core to...
  5. Y

    burnt 13A fused spur

    this would suggest that the new storage heater is connected to the 24hr supply hence the larger electric bill