  1. EFLImpudence

    Wago connectors and ceiling light

    :?: What about connecting it to the other three earth wires? Where are you going to shove the line and neutral?
  2. EFLImpudence

    Double Socket with FCU For Boiler? Recommendations Please

    No. You can always add sockets. Pulling out the plug is complete disconnection/isolation - better than switching off an FCU.
  3. EFLImpudence

    Double Socket with FCU For Boiler? Recommendations Please

    Nothing wrong with that - better in some respects when unplugged. Not sure I understand the question. You can get dual back boxes which allow fitting of one single socket and one FCU.
  4. EFLImpudence

    Replacing ceiling light, confused by wiring

    None actually does that but - they do not use the lamp-holder threads as one of the contacts.
  5. EFLImpudence

    Replacing ceiling light, confused by wiring

    It doesn't really matter.
  6. EFLImpudence

    Replacing ceiling light, confused by wiring

    Wrong way round.
  7. EFLImpudence

    Replacing ceiling light, confused by wiring

    The two black wires together will be the Neutrals. The single black wire will be the (switched)Line(live). The three red wires are the Line(live) loop which must remain connected together but to nothing else. The three Earth wires must be connected together but to nothing else. Only the black...
  8. EFLImpudence

    Outside socket and light options

    Why don't you have two separate spurs; one for the socket and one for the light?
  9. EFLImpudence

    Twin socket extension boat

    Are you sure?
  10. EFLImpudence

    Best way to wire these lights?

    https://flameport.com/electric/lighting_circuits/series_wiring_error.cs4
  11. EFLImpudence

    FCU Wiring/Spur

    But that's not spurring off a spur, is it?
  12. EFLImpudence

    SPD's compulsory

    What have the last few posts been about? Being risk averse. Perhaps you reply to too many threads at once, thus losing track of the points raised.
  13. EFLImpudence

    SPD's compulsory

    With that in mind, do people think I should have a CPC fitted to my circuits? There is only a |CPC in the kitchen socket circuit.
  14. EFLImpudence

    Twin socket extension boat

    Ah. Which are you proposing to use? I replied after seeing this plug. from your link...
  15. EFLImpudence

    Twin socket extension boat

    Please note the edit above.
  16. EFLImpudence

    Twin socket extension boat

    The point is that the Schuko plugs can be inserted upside down thus reversing the polarity. This doesn't matter where a suitably rated circuit over-current protective device is in the Line conductor. The trouble is with the U.K. Ring Circuit which require a fuse in the plug [edit] to be in the...