    Oil combi boiler hot water capacity

    I prefer oil boilers to gas.Bob
  2. O

    Oil combi boiler hot water capacity

    No the woooster won't give that amount of hot water try a grant it's a better boiler get a 21 or 26 kw depending on the size of your house.It's true oil boilers don't modulate like gas boilers so they rely on brawn so to speak they have a heat store which gives a burst of hot water while the...
  3. O

    Oil fired central heating what do I need to know?

    No mystery in oil they don't modulate although some firms make one that does a little bit but not a lot.if you keep your tank free from water and have good filters in the line get the boiler serviced at least once a year and get an OFTEC regd engineer this means you can complain to them all in...
  4. O

    Grant vortex not switching on

    Could be a few things if it's an old boiler could be a faulty low pressure switch or a high limit switch Would be a help to know how old the boiler is.Bob
  5. O

    Oil filter Replacement

    No soldered fittings. With a filter you will need fitting either side to go to 10 mm.Bob
  6. O

    Riello Burner Nozzle Replacement

    May have sucked water through and nagged the oil pump but if a nozzle change is needed then undo the two pox drive screws on the blast tube after removing the burner from boiler and switched off the power pull off the tube you'll see the nozzle 16 mm spanner for nozzle and 17 mm to hold the...
  7. O

    Riello RDB1 - Lockout - Suspect Pump Clogged or Broken

    Oh yes and check for water in the oil aswell.Bob
  8. O

    Riello RDB1 - Lockout - Suspect Pump Clogged or Broken

    No get an engineer in to check out the oil line and then the boiler and burner if you do the lot then you'll be ok for a year.Bob
  9. O

    okay until our oil ran out

    If your selling then you need by law to leave a fully working heating system and you can be liable if it's not.It's in your interest to get in an engineer.Bob
  10. O

    Brrr Oil Boiler Worcester Danesmoor 15/19 on lockout

    Could be capacitor gone or pump has seized up need engineer.Bob
  11. O

    Oil burner locking out - Riello 40

    1 look at the photo cell check it's clean change it if it looks really old.2 check pump pressure and nozzle make sure the nozzles clean it should be changed every year.3 change the coil on the pump it helps to open the valve to allow the oil to the nozzle.4 change the capacitor this helps the...
  12. O

    Mistral Boiler

    Yes you've probably got an oil combi boiler most people leave them on constant and the heating on timed.Bob
  13. O

    Landlords gas certifricate

    God that was funny.Bob
  14. O

    Oil/wood heating ??

    Be careful not to put too big a stove in I've a customer who put in a 7 kw stove in and it was too big it's a pig to run really low.Bob
  15. O

    Unvented water cylinder leak

    Yup get an engineer these things can be deadly your plumber does not know what he's doing.Bob
  16. O

    Oil ran out, bled it now there's no oil flow

    Back blow the oil line with both ends off so it blows right through then clean the filter then connect up and oil should flow.Bob
  17. O

    Trianco Eurostar 100/125 Premium

    I'll tell you what's happened someone had turned the electrodes to the top instead of the side and they were blocking the line of sight for the photocell.Bob
  18. O

    Trianco Eurostar 100/125 Premium

    The different models had a variety of baffles could be theyre in wrong as a rule the bottom baffle fits to the far wall of the chamber with a gap to the front,then the next one with a gap at the back and so on till they're all in simples.Bob