Search results

  1. O

    Heatslave 20/25 oil combi boiler pump issue

    Undo the big chrome screw in the middle of the ch pump it may have an air lock wait till a bit of water dribbles out then tighten up.Bob
  2. O

    Heatslave 20/25 oil combi boiler pump issue

    Move the black lever over to the left the pump should start if not the micro switch in the actuator could be goosed may need new actuator.Bob
  3. O

    Heatslave 20/25 oil combi boiler pump issue

    Check the actuator on the three port valve is working if it's not check the flow switch it could be stuck on and if it is the boiler will stay in hot water mode.Bob
  4. O

    Endoscope down blocked toilet

    Could be a 4" pipe and a 5" turd.Bob
  5. O

    mira gem 88 leaking

    Brill shower I love em Bob
  6. O

    Repressurise Warmflow External Oil Boiler

    Kon the ex vessel there are two flexisthe thicker one leads to a fitting with a tap turn it upwards till the pressure is at 1 1/2 bar that should do it but if you get the pressure up and it don't start then the thin flexible pipe is blocked with crap at the prv end a common fault if system not...
  7. O

    oil fired boiler, flow direction wrong?

    God almighty I'd rip all that pipework out and renew it and the pump takes water away from the boiler.Bob
  8. O

    Bentone oil burner stopping randomly

    Try the coil on the oil pump this sound like the fault which suggests it's faulty.Bob
  9. O

    Crack in plastic fuel oil tank.

    I love steel tanks.Bob
  10. O

    Danesmoor Oil Boiler lockout after running out

    Bleed the oil through or you'll be needing a new fuel pump. The bleed screw is on the front of the pump it's got a screw with a 4 mm Allen hole for a 4 mm alley key loosen it till it's 1/2 way out get a soak cloth and start the boiler when the air bubbles stop it's done mop up tighten screw and...
  11. O

    Crack in plastic fuel oil tank.

    12 years ago wasn't it law for a 2500ltr tank to be bunded.Bob
  12. O

    Worcester Oil heatslave 12/18 cutting out

    Blow the oil line completely out and get rid of all the water in the tank put new filter on and check oil clean then put in new nozzle but clear the oil pipe first check oil pressure and majestic sure the air is right then try it.Bob
  13. O

    Electric vs oil....costs

    I always tell people if you've got an oil combi get a good sized electric shower sooner or later A boiler will break down.Bob
  14. O

    New Riello oil burners

    Read the book and set to the gauge you get with the burner and set the co2 1% lower than the Book says you'll have no probs I've set about 40 up to now and no probs IMHO I think the co2 Settings are too high.Bob.
  15. O

    Riello RDB

    1change capacitor 2 check or change coil 3 check or change nozzle All this after checking for good oil flow and no water. good luck.Bob
  16. O

    Oil burner new liner... Bad smell

    Simply shocking.Bob
  17. O

    Riello RDB

    Check for water in tank
Back