  1. A

    Dual tariff unit

    You have grey tails currently.
  2. A

    C U main cable SWA

    Badly usually ;)
  3. A

    Stairwell lighting went off, needing advice

    something has caused the fuse to blow. Could be the sensor or cable
  4. A

    Converting old heating control to socket

    So you could fit a 10A fuse in the fcu and run almost anything on a single socket. Don’t think there are many things that use the full 13A these days.
  5. A

    Converting old heating control to socket

    Don’t test to the blue ! Test to black or earth
  6. A

    Converting old heating control to socket

    Some where there should be an fcu with 3a fuse to turn it off. The live is the red wire on the left. The hole spacing is designed to fit a single socket. Depends what you want to plug in really or just make it tidy?
  7. A

    Cabling for motorised valves

    "I've extended the CH pipes to where a cylinder would go" Obviously think about summer time (for example). You need boiler hot water to the cylinder when the heating is off. The return can be combined with the CH return. These days you also need a bypass valve, for when all the motorized...
  8. A

    Dual tariff unit

    No, it won't magically switch. You can get external contactors, so I would go with one of them, switched by the signal provided...
  9. A

    Dual tariff unit

    A pic of your cu and meter setup will help.
  10. A

    wiring up a lighting photocell without a neutral wire?

    I think they actually use the voltage drop across the triac to power the electronics
  11. A

    wiring up a lighting photocell without a neutral wire?

    They don’t need neutral, but you must use an incandescent lamp. Sadly no battery to charge. The second the bulb fails or the power goes off, they loose their memory
  12. A

    Gas main earth bonding has been removed

    You would like to hope an EV installer would fix easy and dangerous things when pointed out to them. All of 10 mins to sort. Don’t they have some basic checks / forms to fill in. Says a lot about the ev cowboys too
  13. A

    Kitchen lighting ideas?

    Didn’t need to drill hole for click connector as they fit between light and ceiling in my case
  14. A

    Kitchen lighting ideas?

    Yeah I am liking the panel lights from Www.lights.co.uk 16% off at present. Common to have 13% off offers Got 4 of them now. Over 3 rooms. First 2 purchased in 2021 When replacing 6ft tubes I did have to make the plaster look tidy on the ends. Light output is great. Can’t believe the spread...
  15. A

    Aico alarm wiring instructions

    It would make sense if you wanted 2 neutrals in the cable.
  16. A

    Aico alarm wiring instructions

    I wouldn’t expect grey. That cable (well mine anyway) was around long before 2004 Annoyingly mine has twin blacks I suspect yours is from the 80’s. And mine from the 90s. They used white black for zone valves in the 80s. ACL. Whwre now they use orange grey
  17. A

    Aico alarm wiring instructions

    That cable also used in central heating systems. And also useful for outdoor pir lights (in conduit) Some sparks use red t&e for alarm supply
  18. A

    Aico alarm wiring instructions

    It’s correct for the supply cable 2c+e
  19. A

    Electric Toothbrush (Philips Sonicare)

    sadly charge elsewhere or get one of these https://www.ebay.co.uk/itm/266995066861
  20. A

    New thermostat wires

    you must have drilled though something. or made other changes while you were doing the stat ? Maybe you have drilled thru the upstairs socket circuit, and the boiler is feed off that circuit too. Either way, you need to get that stat off the wall and see what has happened. Also take a close...