  1. hertsboilers

    Potterton Performa 28i

    For most boilers the internal expansion vessels are there for the water in central heating to expand and retract, but for this particular model, the expansion vessel also has another function to store pre heated energy for instant hot water. That is why this model is called "i", instant.
  2. hertsboilers

    Secondary DHW loop on a combi?

    Why reinvent a wheel?
  3. hertsboilers

    Secondary DHW loop on a combi?

    Agree! Go for a system boiler with a unvented cylinder.
  4. hertsboilers

    Potterton boiler fail!!

    Edited: sorry but thought in the gas engineer only forum, original reply deleted.
  5. hertsboilers

    Potterton Performa 28i

    Yes, two connections to the expansion vessel, on Performa 24i and 28i, also Baxi Instant. One connection is flowing in, and another is flowing out.
  6. hertsboilers

    Most efficient water heating settings

    Modern unvented cylinders have good insulation and little heat loss. So even you left the immersion heater always on it will hardly cost your more electrical consumption. It is by the amount of hot water being used by the occupants.
  7. hertsboilers

    Potterton Performa 28i

    You are worrying too much. As I said at the beginning, an external expansion vessel is okay.
  8. hertsboilers

    Potterton Performa 28i

    No the internal EV still has two sections, one is air and another is water
  9. hertsboilers

    Boiler not turning off - Honeywell V4073A valve problem

    Take the valve head off the base (if it is detachable by two screws, not by four screws!), check the spindle rotation, lubricate it if necessary.
  10. hertsboilers

    Potterton Performa 28i

    Ok for an external vessel.
  11. hertsboilers

    Also please check your junk mail folder.

    Also please check your junk mail folder.
  12. hertsboilers

    Sent

    Sent
  13. hertsboilers

    Vaillant EcoMax 835/2 f25 and f32 faults

    F25 is indeed low water pressure related, you need a good boiler service to charge internal EV and check PRV for not leaking.
  14. hertsboilers

    Ecotec Boiler Firing Up the Heating

    The problem is that you as a DIY shouldn't open this boiler case. So ask the coming engineer about 24V link, he will know what I meant. Good luck for you.
  15. hertsboilers

    Baxi 105e fault on hot water sensor

    If you are okay with DIY, boiler case off, isolate cold water in, drain off bit water, and replace a sensor. Make you know which is COLD WATER INLET otherwise you will kill your boiler!
  16. hertsboilers

    Ecotec Boiler Firing Up the Heating

    Newly installed? Call an engineer to check wiring.
  17. hertsboilers

    Nest install - replacing 3 x Honeywell thermostats / programmers

    Of course you only need two Nests, but at least one of them is third generation.
  18. hertsboilers

    Potterton Pro Max HE issue

    Is it a combi Boiler?