  1. hertsboilers

    Boiler on when timer is off (3 port valve replaced)

    While I was working on your mystery wiring you posted your update, well done Sir! The correct wiring only has one, but there are more than one mistake varieties on wirings. I also believe the engineer made a wrong re-connection, but haven't worked out which two were swapped. Anyway, you had a...
  2. hertsboilers

    Boiler casing screw missing for gas safety inspection

    Is it a decorative cover which is not a cover for air chamber to combustion? Don’t understand what is wrong with some engineers!
  3. hertsboilers

    Ecotec (630) DHW pump speed

    The 2 is better than 1, as the pump speed for heating is proportional to the heating output. There is almost no difference on gas consumption.
  4. hertsboilers

    Which thermostat should I adjust for the hot water?

    Solid tap? Unusual! It is a system boiler, and heat only, unless you have e-bus controls.
  5. hertsboilers

    O/t printer??

    @Bunnyman why not print letters on A4 papers and put them inside envelopes with windows? By the way, so far the best home office printer is Epson XP-850. I can't refill the ink cartridges myself so the running costs are next to zero.
  6. hertsboilers

    Worcester Bosch 28CDI issue

    When sparking is happening, the gas valve is supposed to open so is supposed to get a power from the board. So he should have measured this output from the board. Either gas valve, or PCB board.
  7. hertsboilers

    Nest 3rd Generation Heat Link

    link live to the two commons in the heatlink. Use a pair of existing cable between current programmer and thermostat, T1 and T1 to the new Nest stat.
  8. hertsboilers

    Ecotec 4 series wiring

    Switched live to RT Pump to switched live
  9. hertsboilers

    Honeywell T40 Wiring

    I know there is an anticipator in most of mechanical room stats, but didn't know the theory behind. Thanks!
  10. hertsboilers

    Ecotec pro 28 - pressure doing my head in!

    Get a boiler man to re-charge your expansion vessel and check PRV for not leaking.
  11. hertsboilers

    Vaillant 630 system boiler

    Vaillant ecoTEC 6 series don't need external auto by pass. If there are not too many radiators, the internal expansion vessel can cope with.
  12. hertsboilers

    Logic Combi 24 - PCB keeps blowing

    Old boards will be scrapped. Apart from basic checking on the resistances of pump, fan and gas valve, and visual inspection on diverter valves etc, at boiler cold standby status, we normally don't have ability to go further on board diagnosis, ie, element level repairs. So it is better to have...
  13. hertsboilers

    Which heating thermostat?

    Once approaching the setting temperature, the stat switches on off boiler more to get a slow, non-over shoot, approrach.
  14. hertsboilers

    Which heating thermostat?

    Honeywell CM907 then.
  15. hertsboilers

    Which heating thermostat?

    Honeywell 6360B1036.
  16. hertsboilers

    Which heating thermostat?

    TPi over on off switch, you will have an extra 1% saving on gas bill, so why bothered?
  17. hertsboilers

    Vaillant Boiler not warming enough

    OP, you have been lucky so far, as many experienced boiler men on here tried to help you, particularly by @Steelmasons, @The831Bunny, and @picasso. It might be a simple fix, but it is always better by our own diagnosis on site. So it might be the time to call Vaillant their own engineer in.
  18. hertsboilers

    Logic Combi 24 - PCB keeps blowing

    @bernardgreen is the right person to ask for. lol Unless it is an instant blow off, we don't investigate further apart from a visual check, just replace with another board.
  19. hertsboilers

    Which heating thermostat?

    Don't go for Salus, crap on quality. If you don't like TPi by Honeywell, go for a weather compensation control. But it comes a point, what is your boiler make and model, is it a condensing boiler?