Search results

  1. mcmoby69

    How do you handle wise guys?

    Completely agree, but when they get the invoice and it goes quiet, then only suggest it's not working when he rings them? Anyone normal would be back on to the installer and say so in the first instance.
  2. mcmoby69

    How do you handle wise guys?

    Frost stat kicking in? Seriously? I know it's colder further oop norf than I am, but it's far from frost stat weather, or it's set up wrong. If you think they are taking the ****, send a reminder, then a final demand. Then issue court papers. Don't mess about. Easy to do with MCOL. Shouldn't...
  3. mcmoby69

    Valliant boiler help!?

    Ring your landlord and tell him to get it sorted.
  4. mcmoby69

    replacement bell box

    Some Muppet (moi)got a couple of wires wrong in the bell box. I've started needing reading glasses. Climbed up the scaffolding without them. Thought I could see what I was doing. Obviously not! All good and working fine. Thanks for the replies. Much appreciated.
  5. mcmoby69

    replacement bell box

    Just got round to having a go. Wired exactly as shown but I've got a bell tamper fault. Found one of the bell box tamper wires clamped on insulation. Thought it was that, but no. Still got a tamper fault. Any suggestions please? Tia
  6. mcmoby69

    replacement bell box

    going up tomorrow after work, will let you know how i get on.(y)
  7. mcmoby69

    replacement bell box

    hi chaps, hope someone can help. i have an old gardtec370, working fine. wifey has insisted that the aging bell box is replaced due to our shiny new rendering. i bought a texecom premier odyssey 1e from city electrical factors, they told me it would be the same......the orignal bell box is a...
  8. mcmoby69

    Boiler Saga Continues - Probable Leak...(Update 24/12/20 - Trace and Access visit)

    The great British public....... Options given. Choice made . First job was a gash. So only pump to worry about. Out of warranty as they've never had it serviced. Second job is an alpha...... should have put 20 tins in!:whistle:
  9. mcmoby69

    Boiler Saga Continues - Probable Leak...(Update 24/12/20 - Trace and Access visit)

    you need to dose according to water volume, 1 tin in a 200l system probably wont work.
  10. mcmoby69

    Boiler Saga Continues - Probable Leak...(Update 24/12/20 - Trace and Access visit)

    I'd weigh up the cost if the specialists against 10 tins of miracle seal. I've used this twice in desperation. Both big houses, owners refused to have flooring and boards up. 10 tins in each system. No further problems. Proper fix is to find it and cure it.
  11. mcmoby69

    Boiler Saga Continues - Probable Leak...(Update 24/12/20 - Trace and Access visit)

    Yup, along with the brown stains around the speedfit fittings. Looks like multiple tiny leaks, Evaporating away when the heating is on. Could be why the sub floor looks dry.
  12. mcmoby69

    Boiler Saga Continues - Probable Leak...(Update 24/12/20 - Trace and Access visit)

    Drain dye i have used is luminous green. Powder is red, changes when wet. I once lit up a whole hospital basement that was flooded when I dropped a tub full. It turned a local lido green, police and fire engines turned up. They thought it was a chemical leak.
  13. mcmoby69

    Boiler Saga Continues - Probable Leak...(Update 24/12/20 - Trace and Access visit)

    Theres a few spots of verdigris on some copper pipe , possible pinholing.
  14. mcmoby69

    Boiler Saga Continues - Probable Leak...(Update 24/12/20 - Trace and Access visit)

    De pressurize the boiler. Whip the bleed vent out of the top. Pour a big scoop of drain tracing dye in. Bleed vent back in and top it up and bleed. Run boiler look for coloured water inside and outside the boiler and under the floor. Doesn't matter what colour drain dye used.
  15. mcmoby69

    Boiler Saga Continues - Probable Leak...(Update 24/12/20 - Trace and Access visit)

    Youve got to wonder if some clown has left a trv under the floor when that radiator was blanked off.....
  16. mcmoby69

    Phantom Service Engineer

    i advise my customers to cancel their DD, pay the amount into a savings account. pay me £75 for a service +parts each year, and leave the DD running. as the amount builds they have a reserve for repairs etc. a new boiler usually has a manuf. guarantee so the amount builds up quickly. they are...
  17. mcmoby69

    Worcester boiler no light/power

    there should be a way to isolate the boiler in the garage tbh. if an engineer was working on it someone in the house could turn it on again and give him a shock. does sound like both blokes have messed up though. part slingers by the sounds of it.
  18. mcmoby69

    Phantom Service Engineer

    i would have charged you for diagnosing the fault, the cost of the part +20% plus a charge for fitting it. £227all in. he's cheap. maybe the magic parts fairy was on strike and he couldnt get the part to your place without picking it up himself and getting it back to you? you must think his...
  19. mcmoby69

    changing a concealed flush valve

    Check the bellows, button and tubes are ok before you start faffing about with that.
  20. mcmoby69

    Fitting new boiler, do plumbers worry about type of RCD fitted?

    Not happening at mine for a while. Fook that.
Back