  1. mcmoby69

    Intergas boiler

    I fix all the different brands and models of boilers, as a local independent boiler engineer. Took a 14yr old Worcester out of my own house last year and fitted a 36/30 hre. Always fit intergas with customers too. 4 moving parts, so little to go wrong mechanically. Simple boiler but ugly! Bung...
  2. mcmoby69

    Wet rot or dry rot?

    this site looks handy. I've done a fair bit of building joinery repairs over the years. lots of helpful pics here. https://www.wisepropertycare.com/news/dry-rot/difference-between-wet-rot-and-dry-rot/
  3. mcmoby69

    Baxi boiler red light after water switch off

    primatic cylinder maybe? stuck pump, pure coincidence?
  4. mcmoby69

    Baxi 105e hot water fluctuating

    I'd rule out a faulty non return valve on the shower first before pulling the boiler apart.
  5. mcmoby69

    Baxi 105e hot water fluctuating

    Should have said partial blockage tbh. Amount of water going through plate is reduced , water gets up to temp quicker so thermistor acts correctly. It's also possible the shower head needs cleaning or a non return valve is stuck open. Usually the hot side on the shower.
  6. mcmoby69

    New Combi Boiler Pressure loss

    Repressurise, shut boiler off of flow & return, leave for 24 hrs and re open, pressure drop? Leak on system . Pressure up? Boiler.......
  7. mcmoby69

    Glow worm 18sxi pressure problem

    Dare I mention expansion vessel?
  8. mcmoby69

    Plumbers cocked up boiler install?

    what about the single insulated wires that come from the switched spur to the jumble of connectors in a metal back box? thats compliant????? the filling loop is wrong (from what i can see in the picture) if the valve pointing down is attached to the cold water main, then the nonreturn valve is...
  9. mcmoby69

    Vertical designer radiators

    Designer rads, designed to look good.... and they do...... that's about it.
  10. mcmoby69

    Sailing Club shower facility design ideas please.

    Speak to Stuart Turner (pump firm) they'll size and spec want you need.
  11. mcmoby69

    UFH house seems cold

    Typical boiler slinger install then, get it in, get paid and then get the fook out of here! Getting the original installer back might prove difficult........
  12. mcmoby69

    UFH house seems cold

    Nope, that's for the unvented cylinder. The one you're looking for is usually red.
  13. mcmoby69

    Plumbers cocked up boiler install?

    OP says ' I'm moving into a new place' That would suggest they already own it. If the OP has not bought it yet, I would advise to walk away from the purchase, unless it's their dream home and can afford to have the boiler refitted correctly. From the pics I seriously doubt it's been...
  14. mcmoby69

    UFH house seems cold

    Standard size expansion vessel inside the boiler? No extra expansion vessel anywhere?
  15. mcmoby69

    Plumbers cocked up boiler install?

    Ring gassafe and ask for an inspection. Open a big can of whoopass on the installer.
  16. mcmoby69

    Boiler pressure keeps dropping

    Re pressurise the system. Turn off boiler Isolate flow and return under the boiler. Wait 24hrs, if pressure is ok on boiler it's not that, if pressure drops when you open iso valves, the leak is on your system. A few minor weeps that evaporate can also be a cause.
  17. mcmoby69

    Potterton 28i not starting - Advise pleae

    If the boilers been off a while gas valve could be stuck. You need an RGI to test it.
  18. mcmoby69

    Nest, Hive.............am I missing something?

    I can reduce your gas bill by 100%, all you have to do is send me £20, and I will reveal this secret. Form a queue! Smart meters are really dumb, a customer contacted me on Sunday night recently to say his boiler wouldnt work. Went out to fix, his hob wasn't working either. I thought his ecv...
  19. mcmoby69

    Extremely loud banging from central heating in morning

    Is your headboard securely attached?:whistle: