  1. dilalio

    WC Soil Piping needs sorting :-(

    4" Through the wall. Into a branch tee. Up to durgo in the left hand corner. Other socket of tee then goes to pan. Orient branch tee as you can (either vertical or horizontal) Use Rigid pipe over to pan so you use a multi quick or straight pan con from spigot to pipework - not a flexi pan con.
  2. dilalio

    WC Soil Piping needs sorting :-(

    Ever heard the expression... "buying a dog and barking yourself"? The way I said to do it is the way I would do it for a customer. If they had other ideas of their own... I'd still do it and charge them but the onus would be on them! Back to wall pan, Boxing or furniture unit, concealed...
  3. dilalio

    WC Soil Piping needs sorting :-(

    I've already told you what I would do.
  4. dilalio

    WC Soil Piping needs sorting :-(

    You're finding problems where they are unlikely. Catastrophising!
  5. dilalio

    WC Soil Piping needs sorting :-(

    Pipe it properly and it won't block. Don't put wet wipes down it. It can always be rodded from the inspection chamber.
  6. dilalio

    WC Soil Piping needs sorting :-(

    Buy a cistern with a flush plate then all the gubbins can be changed via that. As for durgo, get a push fit mcalpine one so that you can lift off the shelf of the boxing and pull it off the top of the stub stack for maintenance. That's what I'd do. Sell the old bog on ebay. Someone will buy it.
  7. dilalio

    WC Soil Piping needs sorting :-(

    In your situation, I'd be building a box with a concealed cistern and back to wall pan and put a stub stack with an AAV inside the cistern box.
  8. dilalio

    WC Soil Piping needs sorting :-(

    They allow air in, not out. So in principle, an AAV at the top of any dead branches. SVPs can be anywhere along the run as they breathe in and out. Quite often, an anti vac on a basin waste will suffice, but each situation has its own requirements.
  9. dilalio

    WC Soil Piping needs sorting :-(

    I'd put one in. 2" should be ok. As I always say... "it's better to be looking at it than for it!"
  10. dilalio

    WC Soil Piping needs sorting :-(

    Everyone wants a simple solution, but if that won't work... Guess what!
  11. dilalio

    New boiler - what to ask the plumber?

    There are pros and cons to any system. Too many to list here as there'll be some missed. A good installer should ask you as many, if not more, questions than you ask them. Really, all you need to ask is what do they recommend and why. We need to know your lifestyle, expectations and plans...
  12. dilalio

    Viability of retrofit UFH not all at once?

    I think control logic is a little better these days! :rolleyes:
  13. dilalio

    Viability of retrofit UFH not all at once?

    If you're doing a lot of work on the floors it's well worth it. UFH needs much lower flow temp so you'd be future proofing for when we are forced to use low temp heating systems.
  14. dilalio

    Viability of retrofit UFH not all at once?

    You could fit the manifold (which really needs primaries to it, from the boiler in 22mm flow and return). Install the loop for the first room. Run lengths of UFH as tails from the manifold for all the other rooms to positions where they can be picked up later, when doing each additional...
  15. dilalio

    Worcester Bosch Boiler problem

    As I said above. Can't fault what they did for my customer.
  16. dilalio

    Changing Copper Olive on TRV

    New olive. Paste. Ptfe. Whatever it takes. It won't take a lot.
  17. dilalio

    Baxi sparking on flame sensor - Engineer refuses to call Baxi

    If incorrectly connected, when was this done? And how did it happen? Was it after a routine service? Else it would have been an issue from whatever point it was done! So... Think back to when the issue first started to occur!
  18. dilalio

    New radiator valves - no lock shield?

    And that's what should be. A lot of these outlets are constantly looking for cheaper ways to sell stuff not fit for purpose.
  19. dilalio

    New radiator valves - no lock shield?

    These things are sold on looks. You need to spend £££s to get one that also performs as a decent emitter!
  20. dilalio

    Worcester Bosch Boiler problem

    Worcester are usually pretty good with this. I've sent a few customers the FPR route... Including one that had never been registered. They actually registered it for the customer and replaced the Hex FOC! Pretty darn good service, I have to say. Still don't like the boilers though!