    Grant Vortex - oil boiler... smells like gas!

    That's not right he should leave a print out to prove what the boiler is doing.Bob
  2. O

    Ongoing HRM Wallstar lockout problem - oil boiler

    Could be the coil on the solenoid get the engineer to fit a seal not just talk about it also make sure the electrodes aren't in front of the photocell but round the side.Bob
  3. O

    How long does the average Worcester Danesmoor 20/25 oil boiler last?

    Yes Terry that's the one what a belter it was that's why I liked the wooooster it remind me of them they and other boulters were first rate and so are houndsfield boilers.Bob
  4. O

    Whie powder in boiler

    Looks like plaster take the top off and have a look round does the flue go into a chimney,or is the back wall plaster which is loose the first step is always take a good look.Bob
  5. O

    How long does the average Worcester Danesmoor 20/25 oil boiler last?

    I had a boulter boiler which was nearly 50 years old in my old house which was my dads before he died he had it new and when inhibitor came out he used it every three years and flushed it every five years and filled it with a strong mix of inhibitor when I took the old boiler out I put a...
  6. O

    High Limit button tripping on Warmflow Boiler thermostat.

    Some thermostats are more sensitive than others you could get another warm floe whose thermostat will only trip over mark 5.Bob
  7. O

    High Limit button tripping on Warmflow Boiler thermostat.

    It's a safety function I'd leave it if I was you if the boilers ok the flow is ment to be 75-80 c and that would give a return of around 50c which will be fine I'm a warranty engineer fior warmflow have been for years and that's how I set them with no probs. Check the circulating pump make sure...
  8. O

    danesmoor 15/19 no power to oil solenoid

    Yup I've got 10 in my van.Bob
  9. O

    Grant Vortex Eco post empty oil tank

    Repressurise the boiler then undo the bottom screw on the bottom of the oil pump wait till the bubbles stop then tighten the screw then try to start by pressing the reset button.Bob
  10. O

    Drain cock washer size

    You can get em at any plumbing store for pence.Bob
  11. O

    Sewer gases kitchen sink

    Put a Deeper trap on the pipework and it will stop the smell.And put a better trap on the washing machine pipe aswell.Bob
  12. O

    Thin spanner for reducer

    God I'm ****e on a computer
  13. O

    Thin spanner for reducer

    Kamasa spammers are thin section.Bob
  14. O

    CH comes on even when boiler is set to HW only?

    If it's a grant it could be a non return valve sticking
  15. O

    Cream sludge in Magnaclean Pro 2 cap

    Could be limescale affected by the cleaner which has dissolved to a sludge maybe?.Bob
  16. O

    danesmoor 15/19 no power to oil solenoid

    If not control box Bob.
  17. O

    danesmoor 15/19 no power to oil solenoid

    Are you sure it's not the solenoid goosed Bob.
  18. O

    Bentone BF1 will only fire if I hit reset button

    Bf1 burner good bit of kit could be coil or needing service I'd go for coil cheap option.Bob
  19. O

    Any idea what these are?

    I'll bet they are footprint made great make real good tools.Bob
  20. O

    gas boilers, banned from new-build homes by 2025.

    We haven't got the knowhow yet to get the best out of these so called wonder machines and so the running costs are sky high they are unreliable break down and don't produce the power they are meant to if they are why are people taking them out.Bob