  1. M

    Downlights not sitting snugly

    Also...1.5mm t & e not as flexible obviously and can sometimes stop the downlight from seating properly as it is pushing down on the fitting
  2. M

    Downlights not sitting snugly

    Make sure the area around the cutout is clear of any debris inside, also check the spring clip is not hitting a joist and also check the height of the spring clip which you may be able to adjust by moving it up or down on the side of the fitting
  3. M

    Downlighter recommendations

    GU10....all day long
  4. M

    Socket screw caps question?

    Straight in the bin with them
  5. M

    Is this a normal price to quote for so little work?

    https://medium.com/@oceanbcreative/the-ship-repair-man-story-dd959a4469d8
  6. M

    Is this a normal price to quote for so little work?

    I was going to list all the other things but got bored tapping the keyboard. It doesnt stop there, time sourcing materials, paperwork, PPE, Regs books the list goes on, so 0.05% is not a lot.
  7. M

    Garage RCD Intermittant Tripping

    Still a no no
  8. M

    Is this a normal price to quote for so little work?

    An hours work....including 4 years training, diesel, time traveling to job, £350 worth of tools, certificate and knowledge that it is safe......He is not charging enough
  9. M

    Smart Socket

    Make sure to label your double socket 6 amp only
  10. M

    Garage RCD Intermittant Tripping

    So why did you fit a Type AC In your shed? OH yes 2 quid
  11. M

    Is this a simple install?

    I refuse to fit them...Pain in the ass....get yourself a new fitting
  12. M

    Rigid cables pushing downlighs down

    When you say insulation do you mean Selotex? And when pushing the fitting up have you tried feeding the cables up and out of the way instead of just pushing them straight up?
  13. M

    EICR Cost

    3 bed semi about £250-£300 inc vat around Bucks area
  14. M

    Downlighter recommendations

    Auroura, JCC, Colingwood
  15. M

    how best to split 45 amp 3 ways?

    You need to use 4mm not 2.5mm for sockets if it is on 32a MCB
  16. M

    Light switch position

    L
  17. M

    how best to split 45 amp 3 ways?

    What size cable feeds this circuit, if its a minimum of 4mm just make this a 32a radial circuit using 4mm cable to each additional socket as long as all appliances are on a 13a plug as you stated
  18. M

    Two immersion heaters with switched FCUs got very hot

    Anyone that actually sparks for a living knows you should not have an immersion on a 13a sfcu even if it works out at 12.6a load, as running it for the amount of time it takes to heat the water will cause the unit to get very hot and after a while will cause problems. Should be on its own...
  19. M

    Extending ring main and lighting in to new extension

    I don't mind people being told YES you can do it yourself and issue your own cert and do all the testing yourself, Because in a couple of weeks time when everything starts going bang I can charge them a good amount to put it all right and it's all down to the fact they should have got somebody...