  1. F

    Think my flow & return are the wrong way round

    the pump , motorized valves, auto air vent, and pipework in airing cupboard are all in correct position the problem is the pipes between boiler and airing cupboard are crossed over and need changing over under floor boards or where ever you can gain access. turning the pump round...
  2. F

    Mira Sport Electric Shower leaking whilst switched off

    best bet would be to buy a mira sport inlet clamp bracket for a few quid , not hard to fit. ebay
  3. F

    Glow Worm boiler fires up but no heating

    are you sure your not mistaking the hot water cylinder for the hot water boiler take a photo for us
  4. F

    Glow Worm boiler fires up but no heating

    regarding the tank in loft the vent pipe is right on top of overflow pipe outlet and judging by the tide mark on the ball the water was going up the vent and splashing on the overflow pipe
  5. F

    baxi solo 2 pf 80 - Leaking Water

    a solo 2 pf does this aint the new he version it 15 yr old
  6. F

    Worcester 28Si II - CH Not Working!

    http://www.youtube.com/watch?v=8v9yUVgrmPY
  7. F

    Worcester 28Si II - CH Not Working!

    have a look in the boiler faq at top of page theres a piece in there for sticking pump
  8. F

    Worcester 28Si II - CH Not Working!

    the pump is sticking/stuck . its not used when runing hot water, only heating
  9. F

    TRV's top or bottom?

    trv s at may be easier to operate at high level and the valve its self may regulate better but the rad will not work to its full potential , try it sometime
  10. F

    TRV's top or bottom?

    if you want your rads to get hot put them on the bottom, been to a few at different property s that have had new combi and rads with trv,s at top , and all the larger rads had poor circulation in the bottom corner and poor heat output , no amount off balancing would improve them ...
  11. F

    First radiator in loop on open vent system...

    we could do with a bit more info , make /model of boiler and if system is fully pumped or gravity hot water/ pumped heating as its all guess work at moment . and my guess is it has a slight leak on pump valve which is sucking air in when in use
  12. F

    NEW SHOWER VALVE AND HEAD FITTED - PROBLEM

    have you got full pressure at whb taps, does the main stop tap need turning fully on
  13. F

    Curved Ball Valve for Toilet

    or if you dont want to be disturbing any boxing just undo the big nut and put a new washer in...
  14. F

    Boiler losing pressure, cant track where water going!!

    if the pressure dropped when you opened the valves the leak must be on the heating circuit , take the rad valve tops off and check for leaks from the packing gland. thermostatic rad valves are on and off all the time and are notorious for this . press the pin down a...
  15. F

    Radiators warm at top, cold at bottom - NEW SYSTEM !

    near the top of plumbing heating page 1, sticky FAQS
  16. F

    Live streaming

    for anybody else http://www.magictv.co/ free
  17. F

    Do I need a new expansion vessel?

    pump vessel with air and refit, refill system with water to 1 bar and see how it goes , check all rad valves in the mornings when rads are cold for leaks
  18. F

    Do I need a new expansion vessel?

    if the vessel is still off the boiler you would be better pumping it up to 1bar before refitting, it dosnt need to fitted to the boiler first,
  19. F

    help plz hanging a rad on a really nice wall

    use these and couple of beads of mastic under each bracket and it will never sag or work loose http://www.screwfix.com/prods/47347/Fixings/Cavity-Fixings/Fischer-Metal-35mm-Self-Drill-Pack-of-100 drill a pilot hole first