  1. F

    Worcester 24 si II

    if water is just dribbling out the hot tap , then first thing to check is the inlet filter on the flow turbine needs cleaning , tells you how in the installation manual . needs outer casing off
  2. F

    Cold Top Half of Radiator (have bled)

    bleed it with the pump turned off
  3. F

    Baxi 105e pressue not holding

    it needs a new pressure release valve , drain boiler disconnect pipe undue small allen key grub screw and pull , have a towel ready to catch any water
  4. F

    Sludge in hot water cylinder

    the cold water feed tank will either be immediately above hot cyl or in loft its the big one that feeds the hot cylinder . does the hot cyl have lid on top if so its a combined tank and cyl take lid off and check its filling up
  5. F

    Sludge in hot water cylinder

    stop look on the internet and go and see if the cold tank in loft is filling up press the valve down does water rush in :roll:
  6. F

    Baxi 105e No CH or HW Flame Failure and Fault on Flue or Fan

    air pressure switch should do it , boiler does a quick check of parts when first switched on and if the aps was faulty would not go any further , fans usually ok on these ,
  7. F

    Sludge in hot water cylinder

    this is not a sludge problem . check ballvalve in the big tank in loft is filling the tank , then clear the air lock like the plumber did
  8. F

    How do I take off the radiator turner/cap/adjuster/knob PICS

    just pull the white top off or lever it with a screwdriver . underneath if that is the spindle and a small gland nut if that is where the drip is coming from just nip the nut up till you can still turn the valve but no leak . theres no need to dismantle any thing, will take...
  9. F

    blocked radiator

    make sure the heating is turned OFF when bleeding the rads . some rads will sometimes suck air in when pump is running , a common mistake to think the pump needs to be running to push the air out .
  10. F

    More worcester problems

    presure could due topping up a bit
  11. F

    Problem with Drayton SCR after Powercut

    dont know off hand , but heres the instructions properly somewhere in here .cheershttp://www.heatingcontrolsonline.co.uk/instructions/DigistatPlus3.pdf
  12. F

    Radiator flushing using X400

    no harm done , will not due any damage, cheers
  13. F

    Leak on water tank

    hi, drain tank leave compression nut connected slacken lock nut a few turn wrap plenty of ptfe tape round the back it will compress into a washer when tightened up , job done .cheers.
  14. F

    Baxi Combi 80e problem

    then the problem is the cold water pipe to the boiler is frozen somewhere on its run, trace it back , its the small 1/2 inch pipe with a valve on right hand side under boiler , follow this pipe back and if it goes in loft somewhere cold or draughty that where it.ll be frozen ...
  15. F

    Baxi Combi 80e problem

    but have you got any water at all out the hot tap
  16. F

    Baxi Combi 80e problem

    hi are you saying theres no water out the hot tap if so its probably main feed to the boiler frozen does it pass through the loft or somewhere else cold and draughty or if your get cold water out hot tap then probably needs new diaphragm or pin sticking in presure diff valve as already said ...
  17. F

    subsidence , leveling floor

    hi woody . thing with that is the door to the room is at the bottom of the slope so bye the time iv,e fixed furrings to top of joist i would be left with a 3 inch step into the room . cheers.
  18. F

    subsidence , leveling floor

    hi , iv,e got a mid terraced property which has suffered from mining subsidence in the past , now all settled . but has left a fall from back to front of about 3 inchs which due to lay out is only really noticeable in the living room that is the full with of the house , and the door to...
  19. F

    Sime Format 100C Boiler - Timer not working

    ok what i meant was with setting on timer .if you turn the clock dial with your hand clockwise it will simulate the passing of time so in a few secs you can see if the clock is switching the boiler on when it passes 5.30 + 8.00