Search results

  1. H

    Help needed CCTV hikvision

    Bad connection on camera's, have you checked power supply to camera's.
  2. H

    Replacing Burglar Alarm Sensors Covers

    Most white plastic alarm sensors and keypad turn horribly yellow over time. Some worse than others.
  3. H

    Multiple Bells on Pyronix Euro 46

    You will need zem 8+ expanders and additional power supplies . The zem8 + have 4 additional outputs which can be programmed to trigger additional bells and strobes.
  4. H

    Pyronix Enforcer v11 Deltabell

    Another option ,you could put arming/disarm notifications from the app. This will tell you when the alarm is set and unset. You need to turn this function on from your cloud account settings.
  5. H

    Pyronix Enforcer BT Smart Hub 2 and HomeControl app

    Process of elimination. If you have had 2 new wifi cards and are able to move control panel closer to router, then next step would be to change router. Have you still got old router as this didn't cause any issues temporary reconnect it. Do you have option to turn 5GHZ off on the router,this...
  6. H

    Texacom Premier Elite 24 - Honeywell Accenta remote keypad

    No Honeywell keypad will not work on Texecom panels. You need to purchase a Texecom one.
  7. H

    Texecom door contacts - adding another set

    Both contacts need to be close to allow chime to function. If one contact open the other will not chime when opened. Different ways to wire in series.This depends on how zone wiring is setup. Double pole or EOL.
  8. H

    Pyronix Enforcer

    Make zone 1 not used Does it clear mismatch
  9. H

    Pyronix Enforcer

    Wireless device control? is where you would learn and delete devices. Change inputs is where you would change zone configuration A,B etc. Still think it's a programming issue.
  10. H

    Pyronix Enforcer

    Have you relearnt the new device on the same zone ? Mismatch indicates that programming is wrong. Suggest you delete new device ,then check to see that input then has no device registered. Then relearn new device.
  11. H

    Accenta 8 mini can't stop ringing

    Put link between T&A on SCB terminals and then try reset procedure. If this still fails then control panel could be faulty. The battery charging resistor looks OK and not damaged. Control panel not made any more ,spare parts also not available so you would need a replacement.
  12. H

    Accenta 8 mini can't stop ringing

    Having tried both reset procedures could suggest control panel may be faulty. Power down and re Power control panel with battery NOT connected and see if that works.
  13. H

    Accenta 8 mini can't stop ringing

    Default user code 0123 have you tried that ? How and what Default procedure did you try ? Take top cover off pcb and post photo resistor may be burnt out on battery charging circuit.
  14. H

    Enforcer v11 sounds

    It's an on board control panel not a blank end station,therefore it will have a speaker installed.
  15. H

    Enforcer v11 sounds

    Disconnect the piezo sounder in the control panel. To do this you need to open then panel and unplug piezo fly lead.
  16. H

    Home Intruder alarm Battery replacement

    Yes that's fine. 2.1-2.3ah is the only battery to fit your 9448. Your battery charging voltage may be high this could by why you only replaced your existing battery 2 yrs ago.This is a common issue with that control panel.
  17. H

    Home Intruder alarm Battery replacement

    The size of the battery depends on make and model of control panel. What alarm panel have you got. Battery life is usually between 3-5 yrs. What is the voltage output of the battery leads from panel,this can affect the life of battery. Position of control panel can also reduce life of battery...
  18. H

    C & K securitech 800

    What is your budget to replace control panel. Basic would be Texecom Veritas 8R Better would be Texecom elite 24,this is hybrid control panel and can have options for wireless devices via expanders and also can have the option for smartcom,control by an app from a mobile phone.
  19. H

    C & K securitech 800

    This would suggest that the external bell could be faulty and you need to check inside the bell box. The bell test function would also suggest that the siren drive could be faulty also speaker drive could be faulty. Control panel therefore would need replacement.
  20. H

    C & K securitech 800

    Have you a multimeter. What is the voltage between +12v and bell trigger when you do bell test?.