Search results

  1. H

    C & K securitech 800

    To test external sounder remove bell trigger and touch onto 0v,does the bell ring ?. Had a few old 700L where the speakers no longer work. May be faulty speaker and sounder output.Time to look at changing control panel.
  2. H

    Texecom app

    What Texecom connect version are you using V1 or V2 ? What Smartcom firmware version are you using ? What Smartcom is installed Wifi/Ethernet or 4G ?
  3. H

    Gardtec alarm keypad

    Hard to read zone something lost ? Could be battery issue. You could try and read event log for more information but display is really poor. There is an adjustment for the screen on the keypad but don't think it will make any difference to the display .
  4. H

    Gardtec alarm keypad

    Keypad shows Keypad tamper. That is control panel is either a 591,593 or 595 series. Could be 600 ,800 series but don't think so. These are now obsolete. The keypad spring may need adjustment. Keypad tampers are a common fault on that panel.
  5. H

    Euro 46 issue setting alarm with tag

    When you present tag and then press A does it set ?
  6. H

    Haes fire alarm panel

    Looks like a mouse has chewed the ends of the cable. Safety comes first the whole thing should be disconnected and installed correctly. Diy or not I would not risk the Safety of my family with that. Hope you are not putting 999 in the dialler.
  7. H

    Overkill?

  8. H

    Veritas keypad dead? No power?

    Yes,you could have blown the bus data fuse. It's a 500ma 20mm clear quick blow fuse (F4). The internal speaker will sound when you open the control panel,best to get replacement first,would also recommend you get 1amp 20mm as spares incase other fuses have blown.
  9. H

    Accenta 8

    Plenty on Web,just Google accenta installation manuals. To isolate zone might be easier just to put wire link in zone you want to isolate, that way you are not changing any programming functions.
  10. H

    Accenta G3 all PIRs not on

    The burnt resistor is on the battery charging circuit. This would suggest that you had a faulty battery at some stage to cause that damage or your battery is faulty. Disconnect battery and what is the voltage on the battery leads ?
  11. H

    Accenta G3 all PIRs not on

    Check battery output voltage with battery disconnected. Battery charging circuit may be faulty or damaged due to control panel having faulty battery or is faulty.
  12. H

    Replace Flush Door Contact & Updating Texecom

    Would also check little screw that makes contact with micro switch is aligned correctly on outer casing of contact.
  13. H

    eurosec help!

    5678 is the master user 1 factory default code. User manual online to tell you how to change code..
  14. H

    Replace Flush Door Contact & Updating Texecom

    To check contact Set multimeter to ohms Remove contact wires from control panel pcb. Put multimeter onto wires ,with door closed you should get 2.2k reading . With door open you should get 6.8k reading. You can also do this from engineer utilities, view zone status. This will show if door is...
  15. H

    Replace Flush Door Contact & Updating Texecom

    Have you a multimeter to check contact? Is the contact fitted back into door frame correctly. Look on ebay for that contact or source cheaper ungraded contact fit resistors for EOL or change wiring configuration to double pole with ungraded contact. Smart com current firmware 4.02 which can...
  16. H

    Cpx alarm !check code! Help needed (please)

    Service time has been turn on and now requires engineer or anticode reset to restart timer.
  17. H

    Cpx alarm !check code! Help needed (please)

    Press zero button a few times,then what does display show!
  18. H

    Scantronic 9853/2/1 getting old

    You could buy and just swap the plastic case,this will save any programming.
  19. H

    Scantronic 9853/2/1 getting old

    Plastic cases breakdown over the years and become brittle. My bet engineer broke casecehen charging battery? or didn't know how to remove cover !
  20. H

    Texecom 24 disarming problem

    Corrupt data bus. Did the engineer check for induced voltage on keypad cable?
Back
Top