Search results

  1. H

    Texecom Premier Elite W & Smartcom in Spain

    How old is your equipment What software version is your control panel.
  2. H

    Texacom or Pyronix for external / IP devices?

    Used both manufacturers external prox reader and external pir for years.Not had any issues with both. It's all about siting the equipment in the correct position. You need to understand what the IP rating means,not just site in a car wash ?
  3. H

    pyronix manual and Qs

    The tag will be assigned to a different user slot. Event log should show users who set and unset alarm
  4. H

    Texecom panel wifi connect pyronix alarm doesn’t connect to my mobile

    Upgrade your Pyronix enforcer to V11 and have app on your mobile. The Texecom dialler requires a PSTN telephone line to work, as phones are going digital this will no longer work once phone serves have changed(2025)
  5. H

    Alarm that will trigger multiple panels?

    As above. As these are commercial properties they may require certain insurance requirements .
  6. H

    Alarm that will trigger multiple panels?

    Powerline no good if power cut/power turned off. More information required, distance between units What do you mean by external housing? Lots for equipment will work,depends on your budget.
  7. H

    pyronix manual and Qs

    A tag is assigned to a user. When programming a code instead of inputting new code number you present the tag to the keypad. The level of authority depends on how user can use code/tag. Master can control whole system User depends on what level that is set to.
  8. H

    Texecom EOL wiring 2 devices - 1 zone

    That's not advisable with that device, as it recommends not to in the instructions.
  9. H

    pyronix manual and Qs

    46v10 is the correct user manual. 46s = 46 control panel in small control panel housing 46 L = 46 control panel in large control panel housing. What are you wanting to find out what to do ?
  10. H

    Texecom EOL wiring 2 devices - 1 zone

    Instructions state to wire contact on own zone and shock on own zone,otherwise device will not operate correctly. Google shock sensor and Facebook has video on how to wire and setup correctly.
  11. H

    pyronix manual and Qs

    User manual on Pyronix website. Just Google Pyronix euro 46 v10 user manual .It's there 100%.
  12. H

    Hall pir causing alarm on entry. Wireless door sensor

    What device mode is the wireless door contact set to, auto,always awake,hybrid. Should be always awake. Wireless devices take time to respond to control panel. Option would be to set hallway pir as Entry exit,instead of entry route if causing problems.
  13. H

    pyronix manual and Qs

    Control panel could be pyronix 46s or Enforcer with remote keypad. Changing code is same function for both models You need to confirm if system has wifi connection as both panels can work without. Have you a app system I'd?
  14. H

    CP8L - Mains Flt

    Have you done full set of alarm and then unset. Does it say mains fault whilst setting. You need to confirm if 230v is going into panel via fused terminal block and voltage out on orange wires , should be about 18/20volts A/C on orange wires.
  15. H

    CP8L - Mains Flt

    No it's the terminal block at the bottom that the main cable goes into.pull fuse holder out and test fuse is not blown. Test orange wire for power out.
  16. H

    CP8L - Mains Flt

    Have you checked mains fuse inside control panel on the terminal block ? Be careful when testing 230 volts,you should have competent in what you are testing. Have you a multimeter? What is the voltage on the two orange wires on top corner of pcb that come from the mains transformer.
  17. H

    pyronix manual and Qs

    Post photo of alarm control panel
  18. H

    Veritas R8 alarm two tone beep fault

    Sounds power related. How old is the replacement battery you found?,that could be faulty. Testing with multimeter does not prove if battery is ok.
  19. H

    Honeywell PIR not triggering

    You should have fitted contact on door if you wanted to start entry timer instantly. Turn off pet mode to make pir more sensitive. Your choice of detector is not great. Depends on position of sensor to how it will react when entering. The door can act as a shield .
Back
Top