Search results

  1. worcester r35 pcb

    worcester r35 pcb

  2. worcester r35 he plus pcb board

    worcester r35 he plus pcb board

  3. D

    Another 'Rochdale' Issue

    You make some very good points fella,we've had bombers in this country since good old guy fawkes and he a blummin hero, or was he a terrorist,don't get me wrong i don't condone any muppet who wishes to kill for maim in such cowardly acts.As for feeling awkward in certain areas yes i sense it but...
  4. D

    Another 'Rochdale' Issue

    Didnt mean to offend using bradistan, but living in the city you could say its my sense of humour which is shared by my fello hindu, muslim, sikh workmates we all say it and lets face it, it is. As for not hearing about white groomers well i get the impression that anything to do with having a...
  5. D

    Another 'Rochdale' Issue

    kiddy grooming been around for centuries its not a race thing purely mental be it what colour the pervs are, say one thing though you never here of asian girls been groomed maybe because they don't allow them to roam the streets all night and actually care, heres another one kid ran into the...
  6. D

    Can you plumb a shower waste into a rain water drain pipe

    All depends what happens underground if rainwater and soil go together then no problem, i live in third world yorkshire never been pulled by building control, infact given permission by bc when built house extension, got grief making a soakaway in front garden though suppose to inform water...
  7. D

    Fitting a towel rail w/ 600mm tap centres to a 1000mm space

    Its your house do as you like mike, good look with the new house mate hope everything goes well. :)
  8. D

    worcester r35he plus s plan wiring problem

    Hi picasso yes with the tr2 removed the boiler runs constant, with the ability to switch between comfort and eco via the integrated time clock.
  9. D

    worcester r35he plus s plan wiring problem

    Hi matt tried boiler in every mode, set eco temp 5 degree then set clock to constant eco mode, also set timeclock to constant (comfort) to no avail, noticed when boiler showing room temp 11degrees, that time clock also stipulated frost mode activated in manual mode, did wonder if down to...
  10. D

    worcester r35he plus s plan wiring problem

    A quick check would be to make a call for heat via the zone valves then physically pulling either one of the switch wires out of the resistor network connector block if you have wired it the same as my drawing if the heating demand then stops, then its a problem with the wiring if the...
  11. D

    Additional pump on a combi system

    or it may be he is trying to run 15 school radiators all piped with 15mm!
  12. D

    Another 'Rochdale' Issue

    I couldn't agree more live bradford myself look in telegraph at court page loads of no insurance tax mot or licenses, biggest bug of all is the slap on the wrist they get, i mean if you get away without paying insurance for say five years then get a £120 fine your in pocket saved a bundle!
  13. D

    Can you plumb a shower waste into a rain water drain pipe

    wouldn't touch the cast soil, split the rainwater fit hopper run shower waste to hopper :)
  14. D

    HELP!! - RAIN WATER COMING IN VIA BOILER VENT!

    wheres the water coming from gutter?
  15. D

    worcester r35he plus s plan wiring problem

    Hi matt thank you for the diagram, wired as shown in top illustration using the grey and orange from either two port valves to short circuit the 2.2k resistor, everything fine to start with, boiler showing room temp 11 degrees required temp 5 degrees, when call for heat made either zone valve...
  16. D

    worcester r35he plus s plan wiring problem

    Excellent, diagram would greatly be appreciated cheers matt :D
  17. D

    worcester r35he plus s plan wiring problem

    Hi dave it might help if you posted a sketch of how you have wired the system, reading the above i'm persuming you have added two zone valves. I take it that the ufh has its own controller but what is controlling the ch valve? have you also added another room stat? if so then you can fool...
  18. D

    worcester r35he plus s plan wiring problem

    the chap in question is called oldgeeza and he says:- connect a 3.3k resistor between terminals 4 + f this makes boiler think room temp is 11 degrees, then connect a 10k + 2.2k in series between terminals 3+4 this makes boiler operate in frost protection mode, he then connected a volt free stat...
  19. D

    New Install & Boiler Advice.......

    Your a proper gent terry can see why such a large accumulation of thanks been awarded to your veryself, cheers.
  20. D

    New Install & Boiler Advice.......

    Its a r35 he plus discontinued although the guts are pretty much same as the larger greenstars are now.
Back
Top