Search results

  1. Bigsosij

    Pyronix alarm - door sensor issue

    Just leave the lod off and it wont go off again
  2. Bigsosij

    Pyronix Enforcer - How to disable/quieten Mains Failure alarm?

    Yes it will work. Keypad will flash orange but no sound
  3. Bigsosij

    Pyronix alarm - door sensor issue

    Disconnect 1 of the wires then the tamper fault will remain so it wont keep going off until your engineer comes back
  4. Bigsosij

    Pyronix euro46

    If u have learned the contacts to inout 17+18 make sure zem 1 is enabled under INSTALL ZEMS
  5. Bigsosij

    Pyronix Euro 46 Home Control 2.0 App

    Users codes / fobs need to be programmed via manager menu on keypad, so no camnot do via app. Each user when programmed via the keypad will be assigned to areas, i.e A - full set, B night set, depending on what areas you have programmed you can assign areas to users accordingly.
  6. Bigsosij

    Pyronix PIR identification

    The only difference with the pet one is the lense filter. If u got cats then wouldnt bother
  7. Bigsosij

    Pyronix Homecontrol History?

    I dont really see any reason to stay connected once the alarm is set anyway lol
  8. Bigsosij

    Pyronix Homecontrol History?

    That is correct ARC takes priority if cloud priority is set to low (default)
  9. Bigsosij

    Pyronix Homecontrol History?

    His office is probably not using the app module for arc comms. Digi air connected does the app and arc.
  10. Bigsosij

    Pyronix Homecontrol History?

    U can set cloud priority to high instead of low which assume would do what u want but then would it still send a delayed close signal to the arc ? I dont know
  11. Bigsosij

    Pyronix Homecontrol History?

    Yeh it kicks you off to send the signal to the ARC
  12. Bigsosij

    Veritas 8 chimes issue

    And hes gunna come and do it again in 12 months lol
  13. Bigsosij

    Veritas 8 chimes issue

    Im afraid you have indeed had your pants pulled down.
  14. Bigsosij

    Pyronix Homecontrol History?

    The ARC will likely not police a confirmed alarm if the system is not showing as closed (armed) when it is set up to do so. It is not to validate the transmission path, it is so the arc knows of the system is armed or not so can respond to alarms accordingly. If an arc call fails, an alert will...
  15. Bigsosij

    Pyronix Homecontrol History?

    It is not an arc check. Arc call start means a call to the arc has been initiated Arc call ok means the call has been completed and the message has been conveyed to the arc - I.e system set/unset. If the alarm is activated and intruder signal will be conveyed to the arc in the same way. It...
  16. Bigsosij

    Pyronix Homecontrol History?

    When the system is armed, it will send a close signal to the arc. When disarmed will send an open. At default, the output will be programmed as final set all, which means it will only send the close signal if all areas are armed. Your system will never send an open/close signal in this case as...
  17. Bigsosij

    Pyronix Homecontrol History?

    Or just full set and night set. Then the system should send a close signal the the ARC
  18. Bigsosij

    Pyronix Homecontrol History?

    Now try arming areas A,B,C,D simultaneously
  19. Bigsosij

    Pyronix Homecontrol History?

    Have u consulted your installer
Back